Page 38 - Expansion Modules
Re
Expansion Modules
Dependent upon configuration requirements, combinations of the following
Expansion Modules are used with IP Office platforms. With the exception of the
WAN3 module (see page 41), all of these Expansion Modules are connected to
the Expansion Ports of an IP Office platform using Expansion Cables.
Note:
As both the INDeX Media Gateway and the IP Office Expansion Modules
share the same
Expansion
ports on the rear of the IP Office, then, for
each IP Expansion Module used, one less INDeX DSLC can be used.
IP400 Digital Terminal 16/30
Front View (30 Port version)
Unit Status LED
Red = Alive but not initiated
Green = Running OK
DT Ports 9 - 16
DT Ports 25 - 30
Green LED
Connection OK
Yellow LED
(not used)
DT Ports 17 - 24
DT Ports 1 - 8
Note:
The IP400 Digital Terminal 16 Expansion Module is only equipped with the
bottom row of ports (1-16).
Port connections
•
DT ports
are used for connection to Avaya 2000 series telephones and support
either A-Law or
µ
-Law PCM encoding. At default the ports are set to
µ
-Law but
can be switched, in software, to A-Law (refer to the IP Office Administration
Manager Manual for details). Using DT Line Cords (see page 54) and standard
structured wiring, these RJ45 ports can be extended to the required telephone
location. In addition, converters can be used to provide BT New Plan sockets
(431A/631A) if required (see page 63). When devices are equipped with line
cords that terminate in RJ11 plugs, then RJ11/RJ45 adapters should be used.
Rear View
EXPANSION
DTE
Expansion Port
DTE Port
DC Power I/P Socket
DC I/P
- C +
24V DC
2A
Port connections
•
Expansion Port:
Used to connect a Digital Terminal Expansion Module to the
Expansion Port of an IP Office platform.
•
DC Power I/P Socket:
Socket for the external 24V DC unregulated power
supply (supplied with kit).
•
DTE Port:
A 25-way D-type socket. Used for diagnostics only.
Cables
All IP400 Office Digital Terminal variants are supplied with one blue Expansion
Interconnect cable. For Port Pinouts and Cables, refer to pages 49 and 53.
Functional Earth
For Functional Earth connections see page 29.