Installing DECT Base Stations (DBS)
Page 15
Installing DECT Base Stations (DBS)
Correct positioning of Base Stations is vital to the performance of the whole
system. Before installing any DECT Base Station, ensure that you have
accurate plans for its location. If possible consult with the person who
performed the site survey.
Before installing any Base Station check the PCS levels shown on its labels. All the
Base Stations within a system
must
have the same PCS levels.
Note that software level PCS 3+ base stations can be installed up to 2km (1km for
older style units) from the CSLC.
CLSC to MDF Connections
The table below shows the connections from the CSLC cassette's 32-pair cable to
the MDF panel. It is recommended that you connect all 32 pairs even if the
installation does not require all 32. This allows for system expansion and
maintenance with the minimum of cable rewiring
Ensure that the cable and wires are clearly labelled at both ends.
Base Station Wrap Speech Speech
Base Station 1
Orange
White/Blue
Blue/White
Base Station 2
Orange
White/Orange
Orange/White
Base Station 3
Orange
White/Green
Green/White
Base Station 4
Orange
White/Brown
Brown/White
Base Station 5
Orange
White/Slate
Slate/White
Base Station 6
Orange
Red/Blue
Blue/Red
Base Station 7
Orange
Red/Orange
Orange/Red
Base Station 8
Orange
Red/Green
Green/Red
Base Station 9
Orange
Red/Brown
Brown/Red
Base Station 10
Orange
Red/Slate
Slate/Red
Base Station 11
Green
Black/Blue
Blue/Black
Base Station 12
Green
Black/Orange
Orange/Black
Base Station 13
Green
Black/Green
Green/Black
Base Station 14
Green
Black/Brown
Brown/Black
Base Station 15
Green
Black/Slate
Slate/Black
Base Station 16
Green
Yellow/Blue
Blue/Yellow
Installation Manual
Page 15
INDeX CSLC
38DHB0002UKCA – Issue 8 (26/03/2002)