Check

Safety

Before you start the installation, refer to the following 
safety information

• Grounding. Refer to “General grounding 

requirements” on page 5

• Rack mounting. Refer to “Mounting your i120 in a 

rack” on page 3

Installation location

When deciding where to position the i120, ensure 
that:

• It is accessible and cables can be connected easily.

• Cabling is away from sources of electrical noise 

such as radio transmitters, broadcast amplifiers, 
power lines and fluorescent lighting fixtures.

• Water or moisture cannot enter the case of the 

i120.

• There is a free flow of air around the i120 and the 

vents in the sides of the case are not blocked.

Required equipment

Prepare the tools you need to mount the i120 
according to the following table:

• You might also need wire cutters to attach the 

grounding conductors, if your site uses a ground 
block.

• To configure your i120, you will need a computer 

with a screen resolution of 1024x768 pixels or 
higher and either Internet Explorer 6.0 or higher or 
Mozilla Firefox 1.5 or higher.

Unpack

The Avaya Distributed Office i120 is shipped with the 
following items. If any items are missing or damaged, 
contact your supplier. Retain the packaging in case 
you need to ship the i120.

To mount on...

 Prepare these tools

Table

Stylus to fix the feet.

Rack or wall

Phillips head screwdriver.

Flat wall

Screws to fasten i120 to the 
wall.

Uneven wall 

• Plywood board: 16.3” x 

18.3”, 0.8” thick (415 x 
465 mm, 20 mm thick).

• Wood screws.

• Screws to fasten the i120 to 

the board.

Four rubber feet

One Grounding 
Cable Assembly

Power Cord (draw-
ing shows US 
power cord)

Nine 5/16" 
(8 mm) Flat-Head 
Screws

Two mounting 
brackets

Summary of Contents for i20

Page 1: ... your Avaya Distributed Office 4 Connect your Avaya Distributed Office to your telephones computers and network See the Installation Poster Connect your computer to the Services port on the AM110 using an Ethernet cable 5 Power up your Avaya Distributed Office The PWR LED and the CPU LED on the front panel illuminate to indicate that the installation is successful 6 Configure Point your Web browse...

Page 2: ...according to the following table You might also need wire cutters to attach the grounding conductors if your site uses a ground block To configure your i120 you will need a computer with a screen resolution of 1024x768 pixels or higher and either Internet Explorer 6 0 or higher or Mozilla Firefox 1 5 or higher Unpack The Avaya Distributed Office i120 is shipped with the following items If any item...

Page 3: ...s without cable guides to Each side of the front of the i120 so that the front of the i120 is flush with the rack The middle of each side panel of the i120 so that the i120 projects forward from the rack You can attach a mounting bracket with cutouts that guide cables to the side of the i120 These cutouts provide easier access to the front panel and help you manage the placement of the cables To r...

Page 4: ...8 3 0 8 thick 415 x 465 mm 20 mm thick to the wall with wood screws and fasten the i120 to the board Ground To assure safe installation and operation carefully read all requirements recommendations and instructions Pay special attention to all WARNING and DANGER statements V6 V2 V1 V7 V5 V4 V3 US B CO NS OL E RS T AS B Inte rfac e USB Inte rfac e Con sole SYSTEM MD M ALM CP U PW R ET H LA N Por t ...

Page 5: ... and the CE Mark on the product as well as allow a hazard to be present that could result in death or severe personal injury Restricted access location In Finland and Norway the i120 must be installed in a Restricted Access Location due to unreliable earthing concerns A Restricted Access Location is defined as access that can be gained by only Service Personnel or Customers who have been instructe...

Page 6: ...ts power crosses on central office trunks and electrostatic discharge ESD Local electrical installation codes must be followed when installing the i120 DANGER Connection of both grounds through the AC Power Cord and the Supplementary Ground Conductor is required for safe operation of the i120 WARNING An improper ground can cause electrical shock as well as equipment failures and service outages At...

Page 7: ...he level of configuration you need to do Distributed Office Local Manager Main screen If your i120 arrives fully configured the Distributed Office Local Manager Main screen is displayed You may now start using your i120 V7 V5 V4 V3 USB CONSOLE RST ASB Interface USB Interface Conso le SYSTEM MDM ALM CPU PW R ETH LAN Port 10 3 CCA Interface FastE thern et 10 2 Contact Closure 10 1 LIN E 3 LIN E 2 TR...

Page 8: ... the Profile Based Setup Assistant home screen Click Start to run the Profile based Setup Assistant The Profile Based Setup Assistant is displayed the actual screen may differ from this one Initial Setup Assistant Home Screen The Initial Setup Assistant applies to Distributed Office i120 solutions that require complete configuration and should only be reached if the unit was re initialized Check y...

Page 9: ...9 ...

Page 10: ...cumentation 03 600758 and Avaya Support Notices for Hardware Documentation 03 600759 These documents can be accessed on the documentation CD and on the Web site http www avaya com support On the Web site search for the document number in the Search box avaya com COMMUNICATIONS AT THE HEART OF BUSINESS 03 602289 ...

Reviews: