Test 221 PHYs Register -PASSED
Test 271 Ports Internal Loopback -PASSED
If an error is found, the test reports FAILED and an error message is displayed and stored in
the Error Log. The Error Log may contain up to 10 POST (or Burn-In) errors. Use the 'e' —
show errors
command in the Press menu or the Manufacturing
SHOWLOG
command to
display errors. Clear errors using the
INITLOG
command.
If you type
CTRL-C
on the console during the power-up or reset sequence, the Diagnostics
display the following break message:
>>Break Recognized - Wait . .
After Diagnostics finish initializing, the “Press” menu is displayed:
Press 'a' to run Agent Code
Press 'd' to download agent/diag/bootloader code
Press 'e' to display Errors
Press 'i' to initialize config flash
Press 'p' to run POST tests
Press 'r' to reset the box.
If you press . . .
Result
a
Diagnostics executes the Agent code (if present):
Starting Agent Version: 5.0.0.xxx
Decompressing the image done,
Initializing . . . .
d
The following information is required:
Enter Port Number [ <all> ]:
Enter Speed: 10, 100 or 1G [ 100 ]:
Enter Local IP Address [ 0.0.0.0 ]:
Enter Server IP Address [ 0.0.0.0 ]:
Enter Subnet Mask [ 255.255.255.0 ]:
Enter Filename:
e
The POST test errors are re-displayed:
System Resets = 1.
Burn-In Loops = 0.
Burn-In Errors = DISABLED
Default Baud = 9600
Error Log:
Bad Port Mask = 00000000
Loop Test Error Description:
<errors>
i
The flash config/log area is initialized. This area is used by the Agent
code.
p
The POST tests are executed again.
r
Resets the switch
Emergency recovery trees
38 Troubleshooting
March 2013
Comments? [email protected]
Summary of Contents for 3524gt
Page 4: ...4 Troubleshooting March 2013 Comments infodev avaya com...
Page 8: ...Purpose of this document 8 Troubleshooting March 2013 Comments infodev avaya com...
Page 14: ...New in this release 14 Troubleshooting March 2013 Comments infodev avaya com...
Page 16: ...Introduction 16 Troubleshooting March 2013 Comments infodev avaya com...
Page 24: ...Troubleshooting fundamentals 24 Troubleshooting March 2013 Comments infodev avaya com...
Page 50: ...Troubleshooting hardware 50 Troubleshooting March 2013 Comments infodev avaya com...