Avantco SS-2R-HC User Manual Download Page 7

- 7 -

User Manual

• We recommend cleaning the condenser coil at least once per month.
•  Clean the condenser with a commercial condenser coil cleaner, available from any kitchen 

equipment retailer.

Cleaning the Fan Blades and Motor

• If necessary, clean the fan blades and motor with a soft cloth.  
• If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.

Cleaning the Interior of Unit

• When cleaning the cabinet interior, use a solvent of warm water and mild soap.
• Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
•  Wash door gaskets on a regular basis, preferably weekly.  Simply remove the door gasket from the 

frame of the door, soak it in warm water and soap for thirty (30) minutes, then dry with soft cloth 
and replace.

• Check door gaskets for proper seal after they are replaced. 
•  Periodically remove the shelves and shelf brackets from the unit, and clean them with a mild soap 

and warm water.  

Summary of Contents for SS-2R-HC

Page 1: ...178SS1RHC 178SS2RHC 178SS3RHC Freezer model 178SS1FHC 178SS2FHC 178SS3FHC Glass Door Refrigerator model 178SS1RGHC 178SS2RGHC Half Door Refrigerator model 178SS1R2HC 178SS2R4HC Half Door Freezer model...

Page 2: ...CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGE...

Page 3: ...th ship with a right hinged door design If you would like to convert the reach in to a left hinged door design solid door models you must purchase the left hinges seperately Avantco item 178SS1KITFR a...

Page 4: ...surface If the surface is uneven the unit may be noisy The unit may malfunction if the surface is uneven Install the unit in an indoor well ventilated area For best performance maintain 6 of clearanc...

Page 5: ...atures for food safety and should require no adjustments Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freeze...

Page 6: ...es to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated frost Run off water is drained into the evaporator pan...

Page 7: ...aning the Interior of Unit When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the interior fini...

Page 8: ...ocked Re arrange products to allow for proper air flow Make sure there is at least four inches of clearance from the fan Low refrigerant levels Contact a service technician to chek refrigerant levels...

Page 9: ...unit within proper operating conditions specified by Avantco Refrigeration Failure to properly maintain the unit This includes but is not limited to basic preventative maintenance like cleaning the co...