Avantco SS-2R-HC User Manual Download Page 5

- 5 -

User Manual

Electrical

• Please ensure that the required voltage is being supplied at all times.  
•  The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate 

over-current protection.  Please refer to the electrical requirements on the unit’s nameplate.

• The unit should have its own dedicated outlet.
• Do not use extension cords.  
• Ensure the unit is not resting on or against the electrical cord.
• If the unit is not in use for a long period of time, please unplug the unit from the outlet.
• To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
•  After unplugging the unit, wait at least 10 minutes before plugging it back in.  Failure to do so could 

cause damage to the compressor.

Adjusting the Temperature 

Your new refrigerator or freezer is already factory-set to run at optimum temperatures for food 
safety and should require no adjustments. 

Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a 
maximum temperature of 40 degrees Fahrenheit. 

Freezers are set to cycle between a minimum temperature of -5 degrees Fahrenheit and a maximum 
temperature of 2 degrees Fahrenheit.  

Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not 
run constantly at this setting. To change it, follow these instructions:

Digital Control Units
• Hold “SET” for 1 sec. The display will flash the current minimum temperature.
• Use the arrow buttons to adjust the minimum temperature you want it to run at.
• Press “SET” again to save your settings

Always remember to calculate the differential if you change the minimum temperature setting. The 
cabinet temperature will fluctuate up to +7 degrees over your set minimum temperature as the 
compressor runs and shuts off. Setting the temperature too high will result in unsafe maximum 
temperatures and possible health code violations.

Summary of Contents for SS-2R-HC

Page 1: ...178SS1RHC 178SS2RHC 178SS3RHC Freezer model 178SS1FHC 178SS2FHC 178SS3FHC Glass Door Refrigerator model 178SS1RGHC 178SS2RGHC Half Door Refrigerator model 178SS1R2HC 178SS2R4HC Half Door Freezer model...

Page 2: ...CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGE...

Page 3: ...th ship with a right hinged door design If you would like to convert the reach in to a left hinged door design solid door models you must purchase the left hinges seperately Avantco item 178SS1KITFR a...

Page 4: ...surface If the surface is uneven the unit may be noisy The unit may malfunction if the surface is uneven Install the unit in an indoor well ventilated area For best performance maintain 6 of clearanc...

Page 5: ...atures for food safety and should require no adjustments Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freeze...

Page 6: ...es to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated frost Run off water is drained into the evaporator pan...

Page 7: ...aning the Interior of Unit When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the interior fini...

Page 8: ...ocked Re arrange products to allow for proper air flow Make sure there is at least four inches of clearance from the fan Low refrigerant levels Contact a service technician to chek refrigerant levels...

Page 9: ...unit within proper operating conditions specified by Avantco Refrigeration Failure to properly maintain the unit This includes but is not limited to basic preventative maintenance like cleaning the co...

Reviews: