Warning

DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED 
ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. 

DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER 
LES RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE 
CONTENANT LE FRIGORIGENE. 

CAUTION – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIR 
MANUAL/OWNER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY 
PRECAUTIONS MUST BE FOLLOWED. 

ATTENTION – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. 
CONSULTER LE MANUEL DU PROPRIÉTAIRE/GUIDE DE RÉPARATION AVANT DE TENTER UNE 
RÉPARATION. TOUTES LE MESURES DE SÉCURITÉ DOIVENT ÊTRE RESPECTÉES. 

CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; 
FOLLOW HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED. 

ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LA TUBULURE CONTENTANT LE 
FRIGORIGÈNE EST PERFORÉE; SUIVRE LES INSTRUCTIONS DE MANUTENTION AVEC SOIN. LE 
FRIGORIGÈNE EST INFLAMMABLE. 

CAUTION – RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED. FOLLOW 
HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH LOCAL GOVERNMENT 
REGULATIONS. 

ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LE FRIGORIGÈNE EST INFLAMMABLE. 
SUIVRE LES INSTRUCTIONS DE MANUTENTION AVEC SOIN CONFORMÉMENT AUX 
RÈGLEMENTATION GOUVERNEMENTALE LOCAUX. 

Summary of Contents for SS-2R-HC

Page 1: ...178SS1RHC 178SS2RHC 178SS3RHC Freezer model 178SS1FHC 178SS2FHC 178SS3FHC Glass Door Refrigerator model 178SS1RGHC 178SS2RGHC Half Door Refrigerator model 178SS1R2HC 178SS2R4HC Half Door Freezer model...

Page 2: ...CONSULTER LE MANUEL DU PROPRI TAIRE GUIDE DE R PARATION AVANT DE TENTER UNE R PARATION TOUTES LE MESURES DE S CURIT DOIVENT TRE RESPECT ES CAUTION RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGE...

Page 3: ...th ship with a right hinged door design If you would like to convert the reach in to a left hinged door design solid door models you must purchase the left hinges seperately Avantco item 178SS1KITFR a...

Page 4: ...surface If the surface is uneven the unit may be noisy The unit may malfunction if the surface is uneven Install the unit in an indoor well ventilated area For best performance maintain 6 of clearanc...

Page 5: ...atures for food safety and should require no adjustments Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum temperature of 40 degrees Fahrenheit Freeze...

Page 6: ...es to circulate air through the evaporator coil This air circulation raises the coil temperature above the freezing point melting any accumulated frost Run off water is drained into the evaporator pan...

Page 7: ...aning the Interior of Unit When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the interior fini...

Page 8: ...ocked Re arrange products to allow for proper air flow Make sure there is at least four inches of clearance from the fan Low refrigerant levels Contact a service technician to chek refrigerant levels...

Page 9: ...unit within proper operating conditions specified by Avantco Refrigeration Failure to properly maintain the unit This includes but is not limited to basic preventative maintenance like cleaning the co...

Reviews: