1. Refer to the Serial Plate for electrical requirements. These cabinets are rated at 120V 1440W and must be plugged
into a dedicated grounded 120V 15 or 20 Amp outlet.
NOTE: modification of cord and plug will void warranty and may cause the unit to be inoperable.
2. Ensure the power switch is OFF and plug into appropriate outlet.
3. Fill the water pan to 1/2 from the top with clean HOT tap water for Proofing or if moisture is desired for Holding.
NOTE: Check water level every 3 hours (3 hours when Proofing) and refill with clean HOT tap water as necessary.
NOTE: water pan does not have to be used/filled for heating applications that do not require moisture.
NOTE: Proofing mode requires use of water pan to be filled.
HEATING/HOLDING INSTRUCTIONS
CONTROL PANELS
PROOFING INSTRUCTIONS
NOTE:
Settings will need to be adjusted as necessary to reach desired temperature and humidity levels.
NOTE:
The internal air circulation blower and 1440W heating element (controlled with the Heat Thermostat) will operate
continuously when the power switch is turned ON.
A
A
B
B
C
C
D
E
Operating Instructions
1. Set HEAT/PROOF Switch (D) to
HEAT.
2. Set POWER switch (A) to the
ON
position. Power indicator light will turn on.
3. Set TEMPERATURE control (C) to
9
.
4. Pre-heat cabinet until desired temperature is reached (typical heat-up time from 77°F (25°C) ambient to 160°F (71°C)
is approximately 45 minutes). Cabinet temperature reaches 185°F (85°C) within approximately 45 minutes.
5. Re-set TEMPERATURE control (C) and adjust as necessary to reach desired temperature (setting
6-8 is typical for 150°F (66°C) to 160°F (71°C).
6. Adjust HUMIDITY control (E) to desired level. (9 being the highest, 1 the lowest, OFF being no heat to the water)
1. Set HEAT/PROOF Switch (D) to
PROOF.
2. Set POWER switch (A) to the
ON
position. Power indicator light will turn on.
3. Set TEMPERATURE control (C) to
2
.
4. Set HUMIDITY control (E) to
9.
5. Pre-heat cabinet until desired temperature and humidity is reached (typical heat-up time from 77°F (25°C) ambient to
95°F (35°C) and 95% relative humidity is approximately 30 minutes).
6. Adjust HUMIDITY control (E) to desired level. (9 being the highest, 1 the lowest, OFF being no heat to the water)
177HP
177HEAT
Summary of Contents for 177HEAT1836
Page 11: ...User Manual www AvantcoEquipment com 11 Cabinet Assembly 177HPI1836 Diagram...
Page 12: ...User Manual 12 www AvantcoEquipment com Cabinet Assembly 177HPU1836 Diagram...
Page 14: ...User Manual 14 www AvantcoEquipment com Cabinet Assembly 177HEAT1836I Diagram...
Page 15: ...User Manual www AvantcoEquipment com 15 Cabinet Assembly 177HPU1812 Diagram...
Page 19: ...User Manual www AvantcoEquipment com 19 Only HEAT Models 177HEAT Drawer...