16 (32)
.
5.2
Connecting and disconnecting hydraulic hoses
On Avant loaders the hydraulic hoses are connected using the multi connector system. If you have an Avant
300-700 series loader with the conventional quick couplers and wish to change to the multi connector system,
contact your Avant dealer or service point for instructions or installation services.
WARNING
Risk of movement of the attachment and ejection of hydraulic oil - Never connect
or disconnect quick couplings or other hydraulic components while the control
lever of the auxiliary hydraulics control lever is locked on or if the system is
pressurized.
Connecting or disconnecting the hydraulic couplings while the system is
pressurized may lead to unintended movements of the attachment, or ejection of high-
pressure fluid, which can cause serious injuries or burns. Follow safe stopping procedure
before disconnecting hydraulics.
Keep all fittings as clean as possible; use the protective caps on both the attachment and
the loader. Dirt, ice, etc. may make using the fittings significantly more difficult. Never
leave the hoses hanging on the ground; place the couplings onto the holder on the
attachment.
Connecting the multiconnector system:
1.
Align the pins of the attachment connector with corresponding
holes of the loader connector. The multiconnector will not connect
if the attachment connector is upside down.
2.
Connect and lock the multiconnector by turning the lever towards
the loader.
The lever should move easily all the way to its locking position. If the lever does not slide smoothly, check the
alignment and position of the connector and clean the connectors. Also shut down the loader and release the
residual hydraulic pressure.
To disconnect the multiconnector system:
Before disconnecting put the attachment down on a solid and even
surface.
1.
Switch off the auxiliary hydraulics of the loader.
2.
While pushing unlock button, turn the lever to disconnect the
connector.
3.
After ending operation put the multiconnector on its holder on the
attachment.
To connect and disconnect the standard couplings, move the collar at the end of the female fitting. The hoses
should be connected so that the fitting equipped with a coloured cap is connected to the corresponding fitting
of the loader. Note that the protective caps on the loader and the attachment can be fastened to each other
during operation to reduce the accumulation of dirt. When disconnecting the standard quick couplings a small
amount of oil may drip from the couplings. Wear protective gloves and have some cloth at hand to keep the
equipment clean.