least 18 minutes before the next usage.
E02
Resist protection
E02: During the movement, the table vibrates, is
bumped or the table itself is tilted. It immediately
stops the movement. The reverse movement is
automatically released after setting the distance.
Press any key to stop and release the movement
during the reverse running. It should be checked
and ensured that the table does not vibrate
significantly, hit obstacles or tilt and then run.
E10
Motor
abnormal
protection
E10: Power should be removed and rechecked.
Make sure that the motor and the controller
connections are reliable and then plug it back on.
E20
Overload protection
E20: This alarm occurs when running up. Any
heavy objects on the table should be removed
before running. If this alarm occurs when running
down, power off, remove heavy objects from the
table and then power on again.
E31
Under voltage protection
E31,E32: Power should be removed and
rechecked. Make sure, that the power supply to
the controller is secure and then powered back
on.
E32
Overvoltage protection
E60
Out of step protection
Power should be removed and rechecked. Make
sure that
the motors in each channel are identical and their
connection to the controller is reliable and then
powered back on.
If the error message persists after the reset procedure, please contact the supplier.
The initialization procedure must be completed before the first running after the table is
installed or parts are replaced.