Unit 

SI Metric 

Press 

button to display the last height 

unit value set. Use 

 buttons to flip 

between  the  options  (SI,  IN).  After 

selecting  one,  press 

  button  to  save 

the  current  option  value.  Hold  it  for  2 

seconds to exit. 

Inch 

Brightness 

Low 

Press 

button  to  display  the  last 

brightness  unit  value  set.  Use 

 

buttons to flip between the options (L, N, 

H). After selecting one, press 

 button 

to save the current option value. Hold it 

for 2 seconds to exit. 

Normal 

High 

Collision Force 

Off 

Press 

button  to  display  the  last 

collision  velocity  position.  Use 

 

buttons to flip between the options (Off, 

L,  N,  H).  After  selecting  one,  press 

 

button to  save  the  current  option  value. 

Hold it for 2 seconds to exit. 

Light 

Normal 

Heavy 

Seat height 

Original 

Press 

button 

to  enter.  Use 

the 

 

 

buttons  to  flip 

between 

the 

options 

Original,  Low, 

High).    After 

selecting  one, 

press 

 button 

to 

enter 

the 

After 

entering, 

the 

starting  height  of  the 

last  setting  will  be 

displayed. Use the  

  buttons  to  adjust 

it.  Press 

  button  to 

confirm and   save  the 

current 

value. 

Exit 

setting mode.  

Low 

After entering, the last 

height  limit  will  be 

Summary of Contents for DESTIN II

Page 1: ...e 4 Do not place any objects taller than 20 underneath the desk 5 Do not open any of the components the legs control box or switch There is a risk of injury and electric shock 6 Make sure that the power supply is between 100v and 240v before plugging the control box into it 7 This product is designed with a 10 duty cycle 2 min on 18 min off 8 Under no circumstances does the manufacturer accept war...

Page 2: ... the power supply make sure that it s between 100v and 240v any individual parts must be connected before the control box is plugged to the main power supply 6 During operation switch off the main power immediately if the control box makes unusual noises or smells take care that the cables are not damaged unplug the main power cable on mobile equipment before it is moved The usage of cable tie cla...

Page 3: ...d for 5 10 hours the effect will be better the next day When the product is stored it should be tightly sealed Otherwise the 3M glue will fail over time Under the desktop Inside the slot Assembly Instructions I The reset procedure IMPORTANT You must reset the desk before the use Make sure no obstacles are in the desks path Make sure no obstacles are in the desk path Make sure all cords are appropr...

Page 4: ...n H1 will be displayed on the LED display If you release the button the desk will lift from the current height to the sitting position If you press the button H2 will be displayed on the LED display If you release the button the desk will lift from the current height to the standing position IV Awake extinguishing screen To avoid misoperation the LED display of manual control will go to rest after...

Page 5: ...ting Set Height Buzzer switch Beep The function of each button in the setting mode Back button use it to return to the previous menu Switch between options Confirmation button confirm to enter the next level menu of the current interface or confirm the current parameter If the button is not pressed within 20 seconds the setting mode will be exited Tube material Steel Expandable desk frame 46 4 66 ...

Page 6: ...it Normal High Collision Force Off Press button to display the last collision velocity position Use buttons to flip between the options Off L N H After selecting one press button to save the current option value Hold it for 2 seconds to exit Light Normal Heavy Seat height Original Press button to enter Use the buttons to flip between the options Original Low High After selecting one press button t...

Page 7: ...he last buzzer switch status Use button to flip in the options Off On After selecting one press button to save the current option value and keep the current option Hold it for 2 seconds to exit On VII Trouble shooting Down below you can see possible errors which can be displayed The errors will only be displayed when a button is pressed Error code Description Resolve HOT Over heating protection Ho...

Page 8: ...E20 This alarm occurs when running up Any heavy objects on the table should be removed before running If this alarm occurs when running down power off remove heavy objects from the table and then power on again E31 Under voltage protection E31 E32 Power should be removed and rechecked Make sure that the power supply to the controller is secure and then powered back on E32 Overvoltage protection E6...

Reviews: