Operation
2 3
Travis Industries
4050504
1 0 0 - 0 1 1 5 4
Start-Up Sequence
This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started
when cold. This is to ensure proper operation through all possible settings and operational states (hot
or cold, pellets burning or not burning, etc.). This sequence over-rides all user settings (except the
"OFF" position) to set the auger feed rate to medium, the exhaust blower to high, and the igniter on.
"AUGER ON" Light
This light comes on when the auger is turning. This allows the operator to determine when the auger
is turning.
"FAULT" Light
This light comes on when an error occurs:
•
The stove runs out of pellets
•
During initial start-up (for a split second) or for improper electrical frequency
•
A start-up sequence that does not result in the heater coming up to temperature
HEAT OUTPUT
AUTO
OFF
MANUAL
AA
AA
MANUAL
START
FAULT
W
O
L
H
E D
M
I
G
H
W
O
L
H
E D
M
I
G
H
FAN
To reset the fault light, turn the mode switch to off and re-start the stove.
Power Outages
If a sustained power outage occurs while in "Manual", the stove will go to a "cool down" mode to
vacate smoke once power returns. If the power outage was short, the heater will go to the start-up
sequence. If in "Auto", the stove will re-start (if the room is cool).
!
Because this stove relies upon a blower to evacuate the smoke, some smoke may enter
the home during a power outage. To keep to a minimum, leave the door closed.