CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS

 

CONTROL PANEL   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
OPERATING INSTRUCTIONS 

 

 

CONTROL PANEL BUTTONS 

 

1) 

Power On and Off 

- Press the 

POWER 

button once to manually turn the unit on. Press the 

POWER 

button once more to turn the unit off.  

2) 

Mode Selection 

- Press the 

MODE

 Button repeatedly to cycle between the different modes:  Air Condi-

tioner, Dehumidifier, Fan only mode. Each press of the MODE button will light up a different icon on the 
control panel. the exhaust hose and window kit must be installed when the unit is in Air Conditioner, De-
humidifier mode. When using the unit as a fan, it is not necessary to keep the exhaust hose and window kit 
connected to the unit.. 

3) 

Temperature 

- Select the desired temperature by pressing either -

 

or

 +

 

key when using the unit in     

cooling mode. The temperature indicator flashes to display the desired temperature setting. After the tem-
perature is set, the unit will display this temperature setting until it is changed by the user. The temperature 
indicator display shows temperature in Celsius or Fahrenheit.  Press the -

 

and

 +

 simultaneously to change 

between  Celsius and Fahrenheit .

 

4) 

 

Bucket Full

 

- when the unit can not evaporate the collected moisture fast enough. The excess water will 

collect in a backup water tank located inside the unit. The bucket full

 

icon

 

will

 

light

 

up

 

if

 

this

 

occurs

.

 

 

5) 

Louver Direction 

- This unit has 4-way directional louvers. Use the louver guides manually to direct air 

where cooling or fanning is needed most.  

 
 

POWER BUTTON 

MODE BUTTON 

TEMPERATURE AND TIMER   
INDICATOR 

BUCKET FULL  

TIMER/TEMP DECREASE 

TIMER/TEMP INCREASE 

AIR CONDITIONER MODE  

DEHUMIDIFIER MODE  

FAN MODE  

Summary of Contents for AB8K

Page 1: ...8 000 BTU Portable Air Conditioner Operating Instructions Model Number AB8K 3092402 V 130509...

Page 2: ...ual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 M...

Page 3: ...r than the max operating temperature or lower than the minimum operating temperature the air conditioner may not work properly PACKAGE CONTENTS MODEL NUMBER AB8K COOLING CAPACITY 8 000 BTU H DEHUMIDIF...

Page 4: ...unded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if th...

Page 5: ...DIAGRAM Casters Louvers Remote Control Signal Receptor Control Panel on top Filter Compartment Remote Control Evaporator Air Intake Condenser Air Outlet Condenser Air Intake Drain Port Drain Hole Rub...

Page 6: ...up to 7 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both...

Page 7: ...e Portable Air Conditioner above may differ from the unit described in this manual The above directions and images show general directions for Avalon Bay hose portable air conditioners WINDOW KIT INST...

Page 8: ...crews A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 a...

Page 9: ...re by pressing either or key when using the unit in cooling mode The temperature indicator flashes to display the desired temperature setting After the tem perature is set the unit will display this t...

Page 10: ...OL TIMER ON TIMER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED OPERATING THE UNIT USING THE REMOTE CONTROL Remote Colors may differ from t...

Page 11: ...emote control The speeds will cycle through in this order High Medium Low Auto Each change in speed will be associated with a beep sound from the unit The remote control will not display AUTO under th...

Page 12: ...using the Remote control NOTE During hot days the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high Reducing the length of the exhaust...

Page 13: ...coming out of the condensate tank Connect the supplied drainage hose to the back of the unit to aid in drainage into the pan Once the condensate tank is drained the unit will begin working within a f...

Page 14: ...oroughly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being expos...

Page 15: ...ther appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Air and Water Inc Freight and Insurance cost for the warranty service...

Reviews: