Avalon Bay AB8K Operating Instructions Manual Download Page 2

 2 

 

Thank you for choosing a Avalon Bay Portable Air Conditioner. This owner’s manual will provide 
you with valuable information necessary for the proper care and maintenance of your new product. 
Please take a few moments to thoroughly read the instructions and familiarize yourself with all the op-
erational aspects of your new Avalon Bay Portable Air Conditioner.  
 
For your own records, please attach a copy of your sales receipt to this manual.  Also, write the store 
name/location, date purchased, and serial number below:

 

Store Name: ____________________________________________________ 

Location: ______________________________________________________ 

Date Purchased: _________________________________________________ 

Serial Number (located on back of unit): ______________________________

 

IMPORTANT INSTRUCTIONS 
 

Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this 
manual in a safe place for future reference.  

 

1)  Always place the unit on a level surface.  

2)  Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this   manual. 

3)  Maintain at least 10 inches (25 cm) clearance space around this unit.  Do not block or cover air inlet or outlet 

grilles. 

4)  The unit must be connected to a correctly grounded power supply. 

5)  Do not start or stop the unit by inserting or pulling out the power plug.  

6)  Do not use an adapter plug or extension cord. 

7)  Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool. 

8)  Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.  

9)  Do not let children play near this unit. 

10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the 

manufacturer or a qualified service technician.  

11) When cleaning the unit, always turn the unit off and unplug the power cord. 

12) Do Not Mix Old And New Batteries.  

       Do Not Mix Alkaline, Standard (Carbon - Zinc), Or Rechargeable (Nickel - Cadmium) Batteries.

 

 

Summary of Contents for AB8K

Page 1: ...8 000 BTU Portable Air Conditioner Operating Instructions Model Number AB8K 3092402 V 130509...

Page 2: ...ual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 M...

Page 3: ...r than the max operating temperature or lower than the minimum operating temperature the air conditioner may not work properly PACKAGE CONTENTS MODEL NUMBER AB8K COOLING CAPACITY 8 000 BTU H DEHUMIDIF...

Page 4: ...unded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if th...

Page 5: ...DIAGRAM Casters Louvers Remote Control Signal Receptor Control Panel on top Filter Compartment Remote Control Evaporator Air Intake Condenser Air Outlet Condenser Air Intake Drain Port Drain Hole Rub...

Page 6: ...up to 7 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both...

Page 7: ...e Portable Air Conditioner above may differ from the unit described in this manual The above directions and images show general directions for Avalon Bay hose portable air conditioners WINDOW KIT INST...

Page 8: ...crews A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 a...

Page 9: ...re by pressing either or key when using the unit in cooling mode The temperature indicator flashes to display the desired temperature setting After the tem perature is set the unit will display this t...

Page 10: ...OL TIMER ON TIMER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED OPERATING THE UNIT USING THE REMOTE CONTROL Remote Colors may differ from t...

Page 11: ...emote control The speeds will cycle through in this order High Medium Low Auto Each change in speed will be associated with a beep sound from the unit The remote control will not display AUTO under th...

Page 12: ...using the Remote control NOTE During hot days the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high Reducing the length of the exhaust...

Page 13: ...coming out of the condensate tank Connect the supplied drainage hose to the back of the unit to aid in drainage into the pan Once the condensate tank is drained the unit will begin working within a f...

Page 14: ...oroughly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being expos...

Page 15: ...ther appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Air and Water Inc Freight and Insurance cost for the warranty service...

Reviews: