APX-3302 User's Manual (OM110000019A)
-45 -
6.2
Power Over CameraLink
APX-3302 can 12V power source specified to the camera by PoCL standard.
You can control the power supply ON/OFF for each camera independently by software.
In the following case APX-3302 notifies invalid status and stop supplying power automatically.
*APX-3302 cannot detect CameraLink clock from the camera after supplying power within the set time.
*Camera stops CameraLink clock for any causes, and cannot begin to start CameraLink clock with in the
set time.
APX-3302 begins to supply power, if it doesn
’t detect CameraLink clock when the driver starts.
The sequence of the power supply ON is as follows.
Power ON
3s
Wait 3 sec after power supply start
Start Output Clock
+12V
Cameralink Clock
Clock Detect Flag
Ton
If it cannot detect clock detect flag within the set time of Ton,
"Power ON Error" will occur and stop power supply.
Figure6-6: The sequence of the power supply ON