OPERATION COMMANDS

PEDESTRIAN

START

LIGHT
24V / 2W

BUTTON KEY

RX

TX

INTERNAL PHOTOCELLS

EXTERNAL PHOTOCELLS

RX

TX

FLASHLIGHT

230V / 25W

MAX

ELECTRIC LOCK

12VAC/DC 15W

POWER SUPPLY

BIPOLAR THERMOMAGNETIC
 SWITCH WITH DIFFERENTIAL

  6A / 30ma

8

1    2    3    4    5   6    7    8    9   10  11  12  13  14

15  16  17  18  19  20  21  22  23  24  25 

DL1

DL2

DL3

DL4

DL5

DL6

START

STOP

ΝΟ

ΝΟ

ΝC

24V

2W

MAX

ΝΟ

ΝC

COM

+

-

NO

COM

NC

+

-

+

-

NO

COM

NC

+

-

230VAC

COM

CLOSE

OPEN

C

COM

CLOSE

OPEN

Ν

C

TOTAL

 

STOP

C

M1

M2

MOTOR-1

MOTOR-2

20
21
22

23
24
25

16

17

11
12

19

18

1

6,10

2

3

9

1

6,10

7

8

5

4

Summary of Contents for AT-8070-D

Page 1: ...INSTALLATION AND PROGRAMMING MANUAL FOR AT 8070 D CONTROL BOARD FOR 230 Vac SWINGING GATES MOTOR ...

Page 2: ... to make changes to the product without prior notice Therefore thismanualmaynotcorrespondexactlytotheproductspecifications AT 8070 D Control Board for swinging gates DESCRIPTION P1A Operating time programming button P2B Remote control programming button DSW1 Micro Switches TR1 TR2 TR3 Adjustable trimmers RESET Reset Button F2 Low Voltage Fuse TF1 Transformer CN1 Receiver M1 Low Voltage Input Termi...

Page 3: ...osing and you press START button the door opens if the door is opening START command stops the door During auto close START command closes the door If you press START after STOP command the door closes AUTOMATIC If the door is closed or closing and you press START button the door opens START command is ignored while the door is open During auto close START command closes the door If you press STAR...

Page 4: ... LED and the FLASHING LIGHT must turn ON ant then OFF simultaneously For rolling coded remote controls repeat procedure for each control For Fixed coded remotecontrolsjustcopytheremotecontrols Remotecontrolprogramminforpedestrian When the door is closed press until TEST LED starts blinking Do not relase TEST LED starts blinking faster RealeaseRADIO Within10seconds pressthebuttonoftheremotecontroly...

Page 5: ... failure at the first closing of the door the operation time will be greater approximately 12 seconds correctly PROGR speed has began SLOW M2 M 1 M2 M1 M 2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M2 M1 M 2 M1 M2 M1 2 START 3 START 4 START 5 START 6 START 7 START 8 START 9 START 10 START 11 START 12 START 13 START M2 M1 1 START First START command initiates the operation time programming causing the...

Page 6: ...ttings just completed ATTENTION After RESET or power supply failure at the first closing of the door the operation time will be greater approximately 12 seconds PROGR PROGR SLOW M2 M1 M2 M1 1 START 2 START M2 M1 2 START M2 M1 4 START M2 M1 5 START M2 M1 6 START M2 M1 7 START M 2 M1 8 START M2 M1 9 START First START command initiates the operation time programming causing the first motor to OPEN Th...

Page 7: ...ust be issued when the door totally opens Fourth START command defines starting point for slow speed for the door while closing Fifth START command defines the end of the door operation time and must be issued when the door totally closes OPERATION TIME PROGRAMMING FOR SINGLE LEAFED SWINGING GATE WITHOUT SLOW SPEED at maximum needed to move the door correctly Totally close the door Press PROGR unt...

Page 8: ... POWER SUPPLY BIPOLAR THERMOMAGNETIC SWITCH WITH DIFFERENTIAL 6A 30ma 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DL1 DL2 DL3 DL4 DL5 DL6 START STOP ΝΟ ΝΟ ΝC 24V 2W MAX ΝΟ ΝC COM NO COM NC NO COM NC 230VAC COM CLOSE OPEN C COM CLOSE OPEN ΝC TOTAL STOP C M1 M2 MOTOR 1 MOTOR 2 20 21 22 23 24 25 16 17 11 12 19 18 1 6 10 2 3 9 1 6 10 7 8 5 4 ...