Troubleshooting

If a run-time error occurs during heater operation, Autoplugin Key informs about 
the error code with LED flashing. The number of flashes corresponds to the error 
code. See table 2 for the errors description and possible solutions.

Table 2

Error 
Code

Error 

Description

Possible Reasons of 

Error Appearance

Solutions

2

No answer 
from the 
heater 
followed the 
start 
command

Outer temperature is 
higher than +14 Celsius 
degrees

The heater operates only at
temperatures below +15°C. It 
is heater manufacturer
restriction

Fuel level in the fuel 
tank is close to empty 
(“Fuel Low” warning 
indicator is illuminated
in the CIP)

Refuel the car

The heater was blocked 
after several
unsuccessful starts

Try to start the heater in the 
CIP menu. If it doesn’t start
up, make diagnostics of the 
heater.

3

Battery low

The module has 
determined that the
battery voltage is below 
the specified by settings 
items 3.1 or 3.2

Charge car’s battery with 
special charger (or start engine 
to charge) or cancel 3.1/3.2 
module’s settings

4

Time limits 
exceeded 

Time limit for 
autonomous operation of 
the heater is achieved

Run the engine or cancel 1.1 
module’s settings

5

Unsuccessful 
start

The heater was switched 
off spontaneously at 
starting

Make diagnostics of the heater 
if the error appears again

6

Operation 
cycle too 
short 

The heater was switched 
off spontaneously 

Make diagnostics of the heater 
if the error appears again

8

CAN-bus 
error

There is a problem with 
module’s connection to 
the CAN-bus

Check for the module 
connection 

9

Settings error

Settings have been 
stored in the module’s
memory incorrectly

Reset the settings (8.1.1), 
readjust the module

11

Heater no 
connection 

The heater is unplugged 
or out of order

Make diagnostics of the heater