5
Turn the ignition off to exit Setup mode. New settings are saved in the nonvolatile
memory of the module and stored there regardless of whether the module is
connected or not.
Note:
start the engine inside the Setup mode if you want to exit
without saving of new settings.
To reset the module to the factory settings, enter the code 8.1.1. Both direction
indicators in the CIP should flash three times, confirming command execution.
Then the module exits Setup mode and restarts.
Settings table (1)
Settings
Group
Settings
Item
Possible Values
1.
Heater’s
operation
time
1.1.
Limitation of
heater total
operational time in
pre-heat mode
1.1.1
*Not adjusted
1.1.2
40 minutes
1.1.3
50 minutes
1.1.4
60 minutes
1.1.5
70 minutes
1.1.6
80 minutes
1.1.7
90 minutes
1.1.8
100 minutes
1.1.9
120 minutes
1.2.
Limitation of
heater 1-cycle
operational time in
pre-heat mode
1.2.1
10 minutes
1.2.2
15 minutes
1.2.3
20 minutes
1.2.4
25 minutes
1.2.5
30 minutes
1.2.6
40 minutes
1.2.7
50 minutes
1.2.8 *
Not limited by the module
2.
Heater
control with
remote
control key
2.1.
“Lock” and
“Lamp” buttons
functions for heater
control
2.1.1
*”Lock” button for heater start,
“Lamp” button for heater stop
2.1.2
“Lamp” button for heater start, “Lock”
button for heater stop
2.2.
Number of
sequential “Lamp”
button presses for
heater control
2.2.1
Combination is disabled
2.2.2 *
Four presses
2.2.3
Six presses
2.2.4
Eight presses
2.3.
Number of
sequential “Lock”
button presses for
heater control
(when perimeter
lighting is on)
2.3.1
Combination is disabled
2.3.2 *
Two presses
2.3.3
Three presses
2.3.4
Four presses
3.
Battery
Monitoring
3.1.
Minimal battery
voltage that lets the
3.1.1
* Not adjusted
3.1.2
11.8V
3.1.3
11.8V