Autopilot Installation Manual
6.1
Elevator
I-term
shall be set to start value. Tune it following flow chart shown in
figure 6.1.1. Start with high
I-term
and then gradually decrease it, until you
reach satisfactory response.
I-term will add some oscillations, do not worry about this for now. The
D-term
should damp it enough. If you get too much overshoot or too much oscillations
it is possible that you have basic control loop problems as described in 5.4.
1. Set 0 degrees reference angle.
2. Steady state - Wait enough time for con-
troller to stabilize. Around 10 seconds
usually is enough.
3. Step change - Change reference angle by
3-5 degrees. This depends on aircraft. In
our example we choose 4 degrees.
4. Observe the response - Wait approx. 10-
15 seconds.
5. Modify the
I-term
according on the air-
craft response. Please see example tun-
ing on figure 17 for example responses
and appropriate actions.
If you would
like to decrease the response time
I-term
should be decreased.
6. Repeat - Go back to step 1.
Wait 10 seconds
Set Reference to 0°
I = 10.0 s
Wait 10 seconds
Is response
OK?
Step change
Reference = +3-5°
Tune I-term
I = I – 2.0 s
no
yes
D-term
start value shall be set to 0.1s. Then it should be gradually in-
creased, until you reach satisfactory response. The maximum
D-term
should
not exceed 1/5th of a controller
I-term
. To tune
D-term
of the pitch control
loop follow flow chart shown in figure 6.1.1.