2.6.9
Control Panel Configuration
The Control Panel Configuration (CPC) is controlled by the
3rd, 14th, 15th, and 16th bits and is used to set the configura-
tion of the control panel when the CPCS bit is off. If the
CPCS bit (see section 2.6.8) is off, the CPU uses the setting of
the 14th, 15th, and 16th bits to configure the control panel.
Use the following chart to configure the bits.
2.6.10
Setting the Configuration Word
The configuration word can be set from the control panel or
via the serial port from an external controller. This section
describes how to set the adjustable features from a control
panel. Setting the configuration word from an external con-
troller is discussed in section 3.3, “Changing the
Configuration Word Using BCS Commands.”
To set any of the features in the configuration word, place the
distribution matrix in program mode by holding down
<Change> and pressing <Preset> . Both the change and pre-
set LED’s illuminate. Once in program mode, use the 8 Input
and 8 Output keys to set the features of the configuration
word. To exit program mode, press <Cancel>. Figure 2.3
shows the function of each of the input/output keys in the con-
figuration word.
2-10
Chapter 2
AutoPatch
TM
1YDM Series
CANCEL
TAKE
OUTPUT
INPUT
MATRIX
PRESET CHANGE
1
2
3
4
5
6
7
8
9
10 11 12
13 14 15 16
Power ON
figure 2.3 Bits for the adjustable features of the 1Y
Program Mode
Control Panel
Echo (Serial)
Serial
Status
Filter
Sync
Board
Enable
Serial Port 1
0 - Normal
1 - Poll SBC
Serial Port 2
SBC Poll Limit
See table on
page 2-8
Control Panel
Configuration
Scan
Control Panel Number
Scan Configuration
000 - Not Applicable
100 - 4x4
010 - 4x8
110 - 8x4
001 - 8x8
101 - 12x4
011 - 4x12
111 - 15x1
16x16
Front
Panel
Installed