background image

H-13

(A) 

Photo

electric 

sensor

(B) 

Fiber

optic

sensor

(C) 

Door/Area

sensor 

(D) 

Proximity

sensor 

(E) 

Pressure

sensor 

(F) 

Rotary

encoder 

(G) 

Connector/

Socket 

(H)

Temp.

controller

(I)

SSR/

Power

controller

(J) 

Counter 

(K) 

Timer 

(L) 

Panel

meter 

(M)

Tacho/

Speed/ Pulse

meter 

(N)

Display

unit

(O)

Sensor

controller 

(P)

Switching

mode power

supply 

(Q)

Stepper

motor&

Driver&Controller

(R)

Graphic/

Logic

panel

(S)

Field

network

device

(T) 

Software

(U) 

Other

Multi-Channel Module type PID Control

(unit:●mm)

TM

-

B

(Basic module)

TM

-

E

(Expansion module)

TM

-

E

(Expansion module)

※  ①

●Remove●END●cover●for●both●basic●modules●and●expansion●modules.

    ②

●Insert●expansion●connectors.

    ③

●Connect●an●expansion●module●without●space.

    ④

●Fix●the●LOCK●switch●by●pushing●it●in●the●LOCK●direction.

    ⑤

●Mount●the●END●cover●at●each●side.

※ 

Up●to●30●expansion●modules●can●be●connected●to●a●basic●module.●Use●an●adequate●

power●supply●system●for●the●power●input●specifications●and●overall●capacity.

[Maximum●power●(155W=31ea●X●5W)●is●required●●when●connecting●31●units]

●Pull●each●Rail●Lock●switch●up●and●down.

●Insert●the●bolts●to●fix.

●●●●(Tightening●torque●is●0.5N·m●to●0.9N·m.)

● Connector connection

●●Bolt●Inserting

● Multi module connection

 

Dimensions

 

Installation

84.8

110

100

36.6

31.2

32.2

122.3

17

.3

103.4

18.6

2.9

30

Input●sensor

connector

Control●output

connector

Power●/●Communication

connector●(Port●B)

TM -

B

M4●Bolt

110

M4●Bolt

Summary of Contents for TM2-

Page 1: ...tput 2 Channel 2 Alarm1 Alarm2 Relay output 4 Alarm1 Alarm2 Alarm3 Alarm4 Relay output 4 Channel N None No auxiliary input output Item Minimum requirements System IBM PC compatible computer with Intel Pentium Ⅲ or above Operating system Microsoft Windows 98 NT XP Vista 7 Memory 256MB or more Hard disk More than 1GB of free hard disk space VGA 1024 768 or higher resolution display Others RS 232 ser...

Page 2: ...00 Digital input Contact input ON Max 1kΩ OFF Min 100kΩ Non contact input ON Max 1 5V residual voltage OFF Max 0 1mA leakage current Outflow current Approx 0 5mA Control method Heating cooling ON OFF control mode P PI PD PID control mode Heating cooling Hysteresis 1 to 100 0 1 to 100 variable 1 to 100 digit Proportional band P 0 1 to 999 9 Integral time I 0 to 9999 sec Derivative time D 0 to 9999 ...

Page 3: ...VDC 3V 30mA Max SSR OUT2 22VDC 3V 30mA Max SSR OUT3 22VDC 3V 30mA Max SSR OUT4 22VDC 3V 30mA Max RELAY OUT1 250VAC 3A 1a RELAY OUT2 250VAC 3A 1a CONTROL CIRCUIT ADC ADC ADC ADC 1 2 3 4 5 6 13 14 15 16 17 7 8 9 10 11 12 18 19 20 21 22 A A A A B B B B B B B B RTD RTD RTD RTD TC TC TC TC V V V V CH1 IN CH2 IN CH3 IN CH4 IN OUTPUT CIRCUIT 1 2 3 4 5 N C RS485 SOURCE 24VDC A B RS485 CIRCUIT POWER CIRCUI...

Page 4: ... and expansion modules Insert expansion connectors Connect an expansion module without space Fix the LOCK switch by pushing it in the LOCK direction Mount the END cover at each side Up to 30 expansion modules can be connected to a basic module Use an adequate power supply system for the power input specifications and overall capacity Maximum power 155W 31ea X 5W is required when connecting 31 unit...

Page 5: ...ress setting switch SW1 Used to set communication address 5 Communication address group change switch SW2 When communication address is over 16 select 16 Ex For setting 20 address set the communication address group change switch SW as 16 and set the commuicaiton address setting switch SW1 as 4 6 Lock switch Used for fixing units to DIN rail or to the wall 7 Rail Lock Used for fixing each module w...

Page 6: ...to 3272 R PR 9 1 R PR 0 to 1750 32 to 3182 S PR 10 1 S PR 0 to 1750 32 to 3182 N NN 11 1 N NN 200 to 1300 328 to 2372 C TT 1 12 1 C TT 0 to 2300 32 to 4172 G TT 2 13 1 G TT 0 to 2300 32 to 4172 L IC 14 1 L IC H 200 to 900 328 to 1652 15 0 1 L IC L 200 0 to 900 0 328 0 to 1652 0 U CC 16 1 U CC H 200 to 400 328 to 752 17 0 1 U CC L 200 0 to 400 0 328 0 to 752 0 Platinel II 18 1 PLII 0 to 1400 32 to ...

Page 7: ...1 0 1 SENSED CURRENT IN AMPS RMS Io OUTPUT IN VOLTS RMS V 1 10 100 1000 CSTC E80LN CSTC E200LN Do not supply primary current in case that CT output is open High voltage will be generated in CT output The current for above two CTs is 50A same but inner hole sizes are different Please use this your environment Ø23 3 Ø7 7 K Black L White 150 26 5 3 10 5 3 8 unit mm unit mm Ø37 1 Ø13 K Black L White 1...

Page 8: ...body s connections to external units Caution for using Use DC power only Keep the ambient temperature 10 to 50 For more accurate controlling start temperature controlling approx 20 minutes later after connecting input sensors and supplying power In case display accuracy does not meet the specification check Input Bias parameter first Power switch or a circuit breaker must be installed for proper a...

Reviews: