-|Transparent Guide|-
Reset
01.
Press the [◀] + [▲] + [▼] keys for over 5 sec. in run mode, INIT flashes for 0.5
sec.
02.
Press the direction keys to flash NO for 0.5 sec in turn.
03.
Change the setting value as YES by pressing the direction keys.
04.
Press the [MODE] key to reset all parameter values as default and to return
to run mode.
Error
Error display is released automatically when it is in the measured and display range.
Display Description
Troubleshooting
HHHH
Flashes when measurement input is exceeded the
max. allowable input (110 %)
Disconnect power supply
and check the cables.
LLLL
01)
Flashes when measurement input is exceeded the
min. allowable input (-10 %)
D-HH
Turns ON when display input is exceeded high-limit
scale setting value or max. display range (9999)
Reset within the display
range.
D-LL
Turns ON when display input is exceeded low-limit
scale setting value or min. display range (-1999)
F-HH
Turns ON when input frequency is exceeded the
max. display value of measured range
-
OVER
Flashes twice when it exceeds zero range (±99)
and returns to run mode
Reset within the zero range.
01) Displays at DC input model only.
Output Operation Mode
•
H.SET or L.SET is displayed according to the output operation mode setting. In case of output
operation mode as OFF, H.SET and L.SET are not displayed.
•
When changing output operation mode, high-limit / low-limit output setting value, hysteresis
are reset.
MODE
Output operation
Preset output
LO ON
HI ON
GO ON
H.SET
L.SET
H
ON
OFF
H: Hysteresis
OFF
No output
lST
GO
LO
H
L.SET ≥
Display value -
L.SET <
Display value
hST
HI
GO
H
-
H.SET ≤
Display value
H.SET >
Display value
LhST
HI
GO
LO
H
H
L.SET ≥
Display value
H.SET ≤
Display value
L.SET <
Display value
< H.SET
HhST
HI
GO
LO
H
H
L.SET ≤
Display value
H.SET ≤
Display value
L.SET >
Display value
LlST
HI
GO
LO
H
H
L.SET ≥
Display value
H.SET ≥
Display value
H.SET <
Display value
LdST
GO
LO
H
Second L.SET
≥
Display
value
-
L.SET <
Display value
Time Chart
■ Low speed serial output (negative logic)
It outputs current display value as Low-frequency (50 Hz) type.
[Clock frequency: 50 Hz]
t: 20 ms
ta: 0.05 ms
tw: 5 ms
tb: 4.95 ms
Data
Output
ordering
DP
DP
DP
DP
D
D
D
D
C
C
C
C
B
B
B
B
A
A
A
A
Clock
Clock
Data
Latch
Display
Latch
tb
tw
ta
tb
tw
ta
t
Cn-1
Dn-1
Dn
D1
Cn
C1
1
@
3
4
1
H
1
2
H
2
3
L
4
H
5
H
6
H
7
H
8
H
9
L
10
L
11
L
12
H
13
H
14
L
15
H
16 17
18 19
20
DP D
H H H H L
■ BCD Dynamic output (negative logic)
It outputs display value as BCD code.
t
t: 7.8 ms
ta: 0.5 ms
tw: 5 ms
tb: 2.3 ms
Digit signal
Digit
Data
Output data
Display
1
@
3
4
ta
tw
Data
31.2 ms
H
L
H
L
H
H
L
L
H
H
L
H
H
H
H
H
H
H
H
H
H
dot
D
C
B
A
D0
D1
D2
D3
H
L
H
H
tb