6
System Screen
© Copyright Reserved Autonics Co., Ltd.
67
[Save method of input value]
After setting input register as X0 to X3, output register as Y0 to Y3, and device as M0, wire it as
above connection diagram. This is the operation description.
When press no. 2, no. 8, no, B keys at the same time;
The result of key input is that 2nd, 8th, Bth bit of word device M0 turn ON and M0 value of word
device is changed as 0x0904.
6.7.4
7 segment display
This menu is for displaying the set 7 segment output data at SmartStudio.
For 7 segment information, refer to ‘SmartStudio user manual’.
7 segment is not set.
7 segment is set at SmartStudio.
No.
Function and operation
①
Displays whether using 7 segment.
②
Displays the set output register (COM) value.
③
Displays the set output register (SEG) value.
④
Displays the set output device.
⑤
Displays whether using ‘Device Extensions’.