Autometers Systems IC 995 Installation And Operating Manual Download Page 4

1

MEASURE

: displays Line voltage, Phase to Phase, Line Current, Instantaneous 

power, Power factor, Total power and Max demand

2

HARMONIC

: displays Current and Voltage harmonic data to the 31st inst, wave 

form showing comparison of voltage and current and bar graph comparing 
voltage and current  

3

QUALITY

:  displays Crest factor, THFF, K Factor, Unbalanced factor Voltage peak, 

Voltage vector, Current vector

4

ENERGY

: displays Import and Export of Kwh, Kvarh and import of Kvah

5

D.RELAYS

: indicates status of digital relays

6

SOE

: displays time and date of relays which have been activated

7

SETTING

: programming of meter parameters

Selecting Individual parameters

Select Menu

: Move the highlighted feature up or down by pressing the arrows

marked

to the parameters you want to view.

7.2 MEASURE

:  Press the return key 

this will take you to the Line voltage screen.

Press the down key

to view individual parameters. 

01. Phase to Neutral volts
02. Phase to Phase voltage
03. Phase and Total current
04. Instantaneous Kw 
05. Instantaneous Kvar
06. Instantaneous Kva
07. Individual phase Power factor and Total Power factor
08. Total Instantaneous power Kw, Kvar, kva and Total Power factor 
09. Maximum Demand

8

6. Installation

6.1 Voltage Input

Voltage input should be less than 120% normal voltage (100V or 400V), otherwise
please use PT. On the voltage input, please use a 1Amp fuse. The wiring should be
as our diagrams on page 5.  

Mode of wiring

1 element

1P2W

2 element

3P3W               

3 element

3P4W

Match the voltage input with current input, and match the phase and phase
sequence (otherwise the values or signals will be incorrect).

6.2 Current Input 

Normal current input is 5A, for more than 5A you must use Current transformers. 
Make sure that you follow the connection details carefully when connecting the
voltage and current circuits to the meter.

6.3 Installation of Current Transformer 

It is good practice to use a test shorting block where the external current
transformers can be linked out should the meter ever need replacing.

6.4 RS485 Modbus Wiring 

The IC 995 is 

fitted with an RS 485 Modbus output. It has been designed to work

with Autometers protocol version V6.2.17, which enables up to 128 meters to be
connected on one Lan circuit. We advise using Beldon cable 9841 or 9842.

7. Features available 

7.1 Main menu: 

When the meter has voltage applied to the auxiliary
terminals (12 and 13) the meter will go through a
set up routine. Firstly the display will show
Autometers’ front page then it will go to the first
screen (01), the line voltage screen.

Press Menu to view the various optional parameters.

6

7

0 8- 14- 20 0 9

17 45 55

220.0
220.0
220.0
50.00

Volts          

01

L1

L2

L3

F

V

V

V

Hz

0 8- 14- 20 0 9

17 46 15

381.0
381.5
381.5
50.00

Volts       

02

L1-2

L2-3

L3-1

F

V

V

V

Hz

0 8- 14- 20 0 9

17 56 11

04.99
04.99
04.99
14.99

AMPS           03

L1

L2

L3

TTL

A

A

A

A

MEASURE

M
E
N
U

HARMONIC
QUALITY

D.RELAYS
SOE
SETTING

ENERGY

01. Phase to Neutral volts

02. Phase to Phase voltage

03. Phase and Total current

Summary of Contents for IC 995

Page 1: ...ly when used in conjunction with the Autometers Horizon Monitoring System User friendly installation programming and operation make the IC 995 the choice of installers operators and engineers alike Th...

Page 2: ...at 10kWh pulse and 1 RS485 Modbus protocol output in order to satisfy remote meter reading and system control monitoring 3 Technical features FEATURE VALUES Network 1PH2W 3P3W 3P4W Frequency 45 65Hz...

Page 3: ...70v Wiring Electrical and communication connections are made directly to the back of the meter See diagram to right There are three blocks of green connectors the two at the top can be unplugged the o...

Page 4: ...d be as our diagrams on page 5 Mode of wiring 1 element 1P2W 2 element 3P3W 3 element 3P4W Match the voltage input with current input and match the phase and phase sequence otherwise the values or sig...

Page 5: ...am 1 WAVEFORM diagram 2 BAR diagram 3 VALUE To select VALUE move the cursor over the word Value by pressing the key with the arrow facing down and then press return Here you will be able to view the i...

Page 6: ...ance The unbalance voltage or current of 3 phase can be divided into positive component negative component and zero component The screen displays Vu f Voltage unbalanced factor Iuf Current unbalanced...

Page 7: ...the status of the digital inputs and outputs relays The digital input is powered by 5V and digital output is a pair of non powered contacts If programmed the status will change to ON these relays are...

Page 8: ...o you can enter your number in the correct sequence 8 Network Move the highlighted feature up or down by pressing the arrows marked to the Network line The cursor will move over the 3p4w symbol to alt...

Page 9: ...hlighted with the rst number on the left 001 to change this to 015 read below First press the key with the arrow pointing down this will move the cursor one stop to the right Now press the key with th...

Page 10: ...l through the options When you have selected your option press the key with the arrow facing down this will move the cursor to the four digits on the left 0000 this is the time the relay will stay ope...

Reviews: