Page 23
IronHorse GSDA-CM-8 User Manual – 1st Ed. Rev. A – 10/15/19
Parameter
(Item)
Description
Value Range
Units
Default
GSD8-
240-5C
All other
GSD8
drives
85
Alarm2 Logical "OR" Activation
Conditions
(See "Flags" - Table 2 Below)
BCD
0
86
Alarm2 Logical Inverters
(See "Flags" - Table 2 Below)
BCD
0
87
Alarm2 Logical "AND" Activation
Conditions
(See "Flags" - Table 2 Below)
BCD
0
Parameter Memory Command Parameters
95
Restore to Factory Defaults
(Affects Drive Settings Only)
0 = Abort & Exit
5 = Restore Factory Default Settings
0
96
Restore ModularBus Card(s)
Settings to Factory Defaults -
(Card Settings Only)
0 = Abort & Exit
100 = Restore Slot 100 Default
Settings
200 = Restore Slot 200 Default
Settings
500 = Restore Slot 500 Default
Settings
0
98
Save to User Default Memory
Save "Environment" (Drive & All
ModularBus Card Settings) to
"User Save" Storage Area
0 = Abort & Exit
5 = Save User Settings
5 = Copy current Settings TO
"Settings2" (or "Settings1" if using
"Settings2")
0
99
Restore From User Default
Memory
Restore / Swap "Environment"
(Drive & All ModularBus Card
Settings) from "User Save"
Storage Area
0 = Abort & Exit
1 = Restore User Default Settings
5 = Copy (Restore) current Settings
FROM "Settings2" (or "Settings1" if
using "Settings2")
10 = Swap Between "Settings1" &
"Settings2"
0
Maintenance Timer Setup Parameters
100
Activate Maintenance Message -
(After this amount of time)
0 = Off
1 = 1 ~ 9999
Hours
0
101
Reset Maintenance Timer
0 = Abort & Exit
5 = Reset
0
102
Current Value of Maintenance
Timer
Read Only
Hours
0
103
Scale Timer
0 = Disabled
1-9999 = Scale Factor
0
Configuration Parameters
120
Auto/Manual Slot Control
0 = Slot 100
1 = Slot 200
2 = Slot 500
1
121
Follower Target Source
1 = Pickup
2 = Slot 100
3 = Slot 200
4 = Slot 500
1
122
Follower Percent Source
1 = Slot 100
2 = Slot 200
3 = Slot 500
1
Flags - Table #1
0
No Active Flags
1
Accel/Decel Ramp in Progress
2
S1 (Main) Act Spd (Tach) Outside
Alm Limits
4
Target Speet Outside Alarm Limits
8
Target Speed = 0
16
S1 (Main) Pickup is Stalled
32
S2 (Leader) Pickup is Stopped
(Valid Only in "Follower Mode")
64
Jog Function Activated
128
Inhibit Function Activated
256
E-Stop Function Activated