ATS Series Installation Manual
11
NOTE: If unhappy with the speed or travel limit setting,
restart this procedure by clearing the door limit positions as
per below first.
12.2 Clearing the Door Limit Positions
Limit positions can be deleted by:
a. Press the MODE button repetitively until the GEAR
LED is lit.
b. Press and hold the MODE button for 10 secs, let the
MODE button go when the main light stops flashing.
c. The close LED will flash continuously to indicate limits
have been cleared.
NOTE: If no action is taken within 30 seconds, the opener
will return to normal operating mode and restore the original
settings.
d. Follow from CLOSE limit: in 12.1 to set new limit positions.
12.3 Re-profiling the Door
Re-profiling is a simplified way of re-learning the travel
characteristic of a previously setup Limit Switch travel
installation. Re-profiling can be used when the travel
characteristics of the door change due to mechanical
adjustments etc. To initiate a re-profile:
a. Limits must be set.
b. Press the MODE button repetitively until the GEAR
LED is lit.
c. Press and hold the CLOSE button
for two seconds,
the door will open and close by itself to record profile.
12.4 Controller memory reset
To clear the controller by:
a. Pressing and holding MODE button for 10secs while in
limit set mode will cause all control memory to be set to
factory defaults.
b. This excludes transmitters, history log and cycle counters.
If limits are already set, clear limits first by using
12.2 Clearing the door limit positions and then clear
controller via 12.4 Controller memory reset.
tip
12. Setting Limits