Note
: Parameters of the control board have already been set in factory according to ordered configuration.
The most common functions are in
bold
.
GROUP
Parameter
Values
Description
PRDSTD - TRS360
Software Ver
0E 00 04 00 00
Version number of the program implemented in the control board.
◄ Left arrow key
Choice of language for menus. OK to validate.
OK key
Reader simulation (direction A then B).
OPERATION
Status
Display of the 100 last major events, with the date and time of
their occurrence (access to previous
events with ► and ▲ keys).
No Diag
No diagnosis.
Power Up
Power on.
Power Down
Power off.
Short Circuit
Detection of short-circuit on the digital outputs.
Save Mem1
Manual saving of the values to Memory 1.
Save Mem2
Manual saving of the values to Memory 2.
Load Default
Loading of default values.
Load Mem1
Manual loading of values from Memory 1.
Load Mem2
Manual loading of values from Memory 2.
Time Adjust
Change of date and time.
Access Level Chg
Change of access level ("OPTION ► "Code").
Download Chg Lv1
Level 1 modification to program.
Download Chg Lv2
Level 2 modification to program.
Download Chg Lv3
Level 3 modification to program.
Reset Counters
Zeroing of counter 2.
In Service
Apparatus in service.
Out Of Service
Apparatus out of service.
Emergency
Apparatus in Evacuation mode (free in both directions).
Test
Apparatus in Test mode.
Maintenance
Apparatus in Maintenance mode.
Default LSA
Limit switch A defect. The turnstile remains in service.
Default LSB
Limit switch B defect. The turnstile remains in service.
Temperature
Display of temperature within casing.
Counter 1
Total number of passages in Directions A and B.
Counter 2
Total number of passages in Directions A and B since last
reset to zero.
Reset counter 2
Yes
Zeroing of counter 2.
Autoriz. A nº
Number of authorizations in progress in Direction A.
Autoriz. B nº
Number of authorizations in progress in Direction A.
Gate State
Indicates the current status of the apparatus.
Emergency
Apparatus in evacuation mode (free in both directions).
Test
Apparatus in Test mode.
Maintenance
Apparatus in Maintenance mode.
In Service
Apparatus
in service (configuration in “EXPLOITATION” group).
Out of service
Apparatus out of service (locked in both directions):
command received on Input DI5.
Pass A State
Indicates the status in which the apparatus is when it is in service,
for this direction of passage. The configuration is carried out in the
“EXPLOITATION” group.
Locked
Obstacle locked: passage in this direction impossible.
Free
Obstacle unlocked: passage in this direction free and without
control.
Controlled
The obstacle is unlocked to release the passage, once authorized
by the card reader.
Pass B State
Same as
“Pass A State”, for Direction B.
Locked
Free
Controlled