5.7. ELECTRICAL CONNECTIONS AND INITIAL POWER-UP
4:17
4:18
4:19
IN
Fig. 8 Left electronic support
• The electrical connections must be carried out in accordance with the diagram provided with the equipment.
• Make sure that the power supply cables are not live. All the internal connections have already been made in the
factory.
• Cut off the excess cable length if necessary; connect the 230V single-phase power supply wires to the main switch
terminals (4:18) and the ground wire to the adjacent terminal
(Fig. 8, page 8 (4:19))
.
• Check that the equipment is properly grounded (casing, etc.)
• Make any other connections according to the specifications of the installation (control cables, etc.)
• Check that there are no cables that could break or be damaged by the movement of the mechanism, and that they
all are properly held in the trunking or wire clamps provided for this purpose.
5.8. CHECKLIST
• Check if all wires are firmly connected to their respective terminal blocks.
• Check the free movement of the tripod when the power to the equipment is turned off in the case of a mechanical
system with an anti-panic device
("type 5" or "type 3")
.
• Check if all screws and nuts have been tightened firmly.
• Check that you have not left any tools inside the gate.
• Remove any foreign bodies from inside the casing
(packaging, scraps etc.)
, and clean it.
• Turn on the equipment by switching the main switch (4:18) [to the ON position].
• Put in place the rear and front end boxes
(Fig. 5, page 6 (4:3) and (4:2))
.
• Install and lock the cover
.
• Check the functionalities (Pictograms, locking mechanism, fraud detection.. performing a few passages in both
directions.
The tripod turnstile is now operational. All the settings have been made in the factory at the time of the working tests.
Some additional adjustment could nevertheless be necessary as a result of transport or handling during assembly. In
such cases, refer to the Technical Manual.
5.8.1.
Functional test
The tripods are delivered from factory on a
controlled mode configuration
in both direction (passage authorisation
through a reader or push button).
Five push buttons located on the AS1635 control board allow to modify the configuration, choosing between free/
controlled/ locked mode on both direction:
•
Press the central
OK
button (= SW6) for 2 seconds to switch to the Configuration mode. To exit this mode, press
the
OK
button again for 2 seconds or wait for 1 minute.
•
Briefly press the Right button (
SW3
) to display the sub-menu, beginning with
md-A
.
•
Use the Up (
= SW4
) and Down (
= SW5
) buttons to navigate within the sub-menu and access
md-b
•
Press the right button (
SW4
) again to display the contents of the parameters
CLOS
,
FrEE
or
CtrL
and the Up
and Down button to modify the setting. Confirm the new setting with
OK
(SW6):