MAINTENANCE
10
WHEELCHAIR LIFT
DEVICE
SP 1400
MODEL
24
10.1
PERIODIC INSPECTION
PERIODIC INSPECTIONS MUST ONLY BE PERFORMED BY SUITABLY
QUALIFIED PERSONS.
Every 12 months the user must have the lift inspected by a suitably qualified technician.
The inspections consist of a visual inspection to check the:
1. Load-bearing frame;
2. Lifting mechanism and relative couplings;
3. Controls;
4. Safety devices;
The inspections must also include:
1. Operating tests;
2. Maintenance;
3. Adjustments.
4. Every periodic inspection must include a load test with (1) lifting cycle at maximum load (simulated).
Any comments concerning the safety of the lift must be recorded in a specific register (see enclosed
facsimile copy) which the user must keep safe for reference in the event of an accident.
The inspection records must also include the following information:
-
Inspection date;
-
ID details and serial number of the inspected lift;
-
Next inspection date;
-
Identification and signature of the person responsible for the inspection.
Whether the periodic inspection highlights any defects, signs of wear or other damage which could
compromise the safety of the lift. In the event of an immediate safety hazard, the user must place the ramp
out of use until the fault has been eliminated.
Defects or damages must be reported to the manufacturer AUTOLIFT srl who will take any appropriate
measures.