MAINTENANCE AND SERVICE
AIR24L
11
2.3
Monthly
-
Inspect non-return valve(clean or replace as
required).
Caution: Ensure that air the tank is empty for this
operation.
-
Manually test the safety valve by pulling the
ring.
2.4
Three Monthly
-
Change oil
-
Tighten cylinder head bolts.
-
Clean and check valve assembly, replace
gaskets/ valves if worn or damaged.
Recommend compressor oil: Use SAE30
for temperatures over 10°C and use SAE10
below 10°C.
3.
Storage
3.1
Unplug the machine and ensure all equipment
disconnected and ventilated.
3.2
Ensure the compressor cannot be accidently
started up again.
3.3
Store in a dry location as moisture can damage
the vessel.
3.4
Always store upright never tilted.
4. Pressure release
To release the excess pressure in the vessel after
use, connect an air tool and run in idle mode until
excess pressure has dissipated.
Maintenance and service
Pull out plug before performing any cleaning or
maintenance work.
Wait for the equipment to cool down before
any work to avoid burns.
Always depressurize the equipment before
carrying out cleaning or maintenance.
1.
Cleaning
1.1
The equipment must be kept as free of dirt
and dust as possible.
1.2
It is recommended that the equipment is
cleaned immediately after you use it.
1.3
Do not clean the compressor with water,
solvents or the like.
1.4
Clean the filter at least every 80 operating
hours
2.
Maintenance work
Warning: Before maintenance operation, stop
the air compressor, disconnect the unit from
the mains supply and discharge all air in the air
tank.
2.1
Daily
-
Check oil level before each use.
-
Drain the condensation from the air receiver.
-
Check for air leaks.
2.2
Weekly
-
Remove air filter element and clean or replace
as required.