20036 - 20038 Page 21
Page 20 20036 - 20038
FACTORY SETTING
OPTION SETTING
Option #
(2 Flashes)
(1 Flash)
Option 20
Accessory Pulse
Dome Lamp
Accessory pulse puts out a brief pulse output after the remote starter starts or stops the
vehicle. When set, this output can be used to turn on a defroster that requires a
momentary pulse or could be used to control GM RAP (retained accessory power)
output. Dome lamp will come on when you unlock the door for 20 seconds
Option 21
Trunk
Carb output
Converts the Green/White wire, normally the trunk output, into an output that will
control a carburetor solenoid. Set this option if you plan on using a carburetor kit to
pump the gas pedal before starting the car with the remote starter.
Option 22
Horn - Relay
Trunk - Relay
Trunk - Transistor
Horn - Transistor
Factory: Blue wire (+12 volt relay output) has Horn function
& Green/White wire (neg. transistor) has Trunk function
Option: Blue wire (+12 volt relay output) has Trunk function
& Green/White wire (neg. transistor) has Horn function
Option 23
Negative Door Pin
Positive Door Pin
This option will change the polarity of the door pin switch input.
Option 24
Alarm Mode
No Alarm Mode
This option will turn off the alarm features if not desired.
Options 25-30
N/A
Options 31
Reset all
PROGRAMMING OPTIONS:
If you do not want any special features -- DO NOTHING and skip this
section. If you want to change to one of the options, TURN THE CON-
TROL SWITCH OFF and make sure dip switch #1 and #2 are up (Off).
Wait 6 seconds for the Green LED on the remote starter module (or the
external LED) to stop flashing and then continue with the following pro-
cedures:
* Set programming switches (4, 5, 6, 7 & 8) to the correct order for the
first item you would like to set. All five switches must be set accord-
ing to the chart on the next page.
FACTORY SETTING
OPTION SETTING
Option #
(2 Flashes)
(1 Flash)
Option 7
Enable Required
No Enable Required
The AutoCommand has a safety feature which requires the user to ‘set’ the control
switch by turning it off and on once each time the user leaves the vehicle. This is
called ‘enabling the unit’. You can disable this feature by choosing the option “no
enable required”.
Option 8
Normal
Daytime Running Lights
This option will turn the headlights on about 10 seconds after it sees the key in the
ignition position -- and turn if off when the key is removed from the ignition.
Option 9
Normal
Diesel “Wait to Start”
This option will control the time before cranking the diesel vehicle by looking at the
‘wait to start’ light of the vehicle. Simply hook the Red/Black Input wire of Step 9 up
to the wire behind the ‘wait to start’ light. Also set option 6 for diesels.
Option 10
Normal
IGN 2 off during Crank
This option will turn off IGN 2 during crank. This is required on some newer vehicles.
Option 11
Horn Pulsing
Siren Constant
Changes the thin blue wire from pulsing output for horn to constant output for a siren.
Option 12
Chirp with locks
Silent lock/unlock/start
This option will eliminate the chirp with Start, Lock and Unlock.
Option 13
Active Arming
Passive Arming
Active arming--Requires the owner to actively arm the car with the remote control.
Passive arming--Automatic arming after the key is removed and the door is closed.
Option 14
Normal
Lock Follow Ignition
This option locks the door when the key is in the ignition.
Option 15
Normal
Unlock Follow Ignition
Selecting this option will unlock doors when key is removed from ignition.
Option 16
Normal
Double Lock Pulse
This option will pulse the lock output wire twice instead of once for normal mode.
Option 17
Normal
Double Unlock Pulse
This option will pulse the unlock output wire twice instead of once for normal mode.
Option 18
Short lock pulse
Long lock pulse
This option will increase the door lock time from 0.6 seconds to 3 seconds for vehicles
with vacuum locking systems. (many European vehicles).
Option 19
N/A