PART 5 MAINTENANCE
The AutoAnchor does not contain any user servicable parts.
User maintenance is limited to :
• Checking all cables and connections for signs of wear or damage and replacing them as
necessary.
• Checking the sensor head is not worn and has not moved out of alignment with the
magnet and replacing the sensor if necessary.
After any sensor repairs or changes to
sensor installation reset the sensor by clearing to zero twice.
• Checking the magnet is not worn or corroded and replacing the magnet if necessary.
Note: Do not use chemical or abrasive materials to clean the console unit. If it is dirty wipe
it with a clean damp cloth. Avoid wiping the display screen with a dry cloth as this could
scratch the screen.
REPLACING THE BATTERY IN THE AA710 CONSOLE
Replace the batteries when the battery indicator shows the battery level
is low. Do not allow the battery level to fall to zero. Two alkaline AA 1.5V
batteries are required.
Turn off the console and turn off the power to the base station. Open
the console case by removing the screws and lifting off the back cover.
Remove the used batteries and replace them with new batteries in the
same position. Check that the perimeter seal is clean and undamaged.
Put the cover in place, refit the screws and tighten.
Do not overtighten
the screws.
Note: User settings are not affected by power loss or changing the
batteries.
Battery Indicator
Battery Care
Insert batteries with the correct polarity.
Replace both batteries at the same time.
Do not mix old and new batteries or different types or brands of batteries.
Remove exhausted batteries immediately from the device.
Remove batteries and store separately if an extended period of non use is anticipated.
Follow battery manufacturer’s instructions for disposal of used batteries.
38