CABLE SPECIFICATIONS
An appropriate multi-core cable must be used to maintain the cable gland
seal into the base station.
Total Length
Cable Size
Cable from AA702 Base Station to the Power Supply
Less than 8 m (26 ft)
1.5mm
2
(AWG16)
8 m (26 ft) - 11 m (36ft)
2.0mm
2
(AWG14)
11 m (36 ft) - 17m (56 ft)
2.5mm
2
(AWG12)
Cable from AA702 Base Station to Outputs
Less than 10 m (33 ft)
1.5mm
2
(AWG16)
10 m (33 ft) and 20 m (66 ft)
2.0mm
2
(AWG14)
20 m (66 ft) and 40 m (132 ft)
2.5mm
2
(AWG12)
Cable from Motor Load Wires
Up to 30.5 m (100 ft)
1.0mm
2
(AWG18)
WIRING
Plug In Sensor Connections
The AA701 Base Station and the sensor are prefitted with connector plugs. The 2m sensor
cable plugs direct into the base station. Extension cables are available.
Field Connector Plugs:
Required for the sensor cable if there is no plug connected eg
AA black sensors or reed switch sensors. The field connector is soldered to the wires and
provides an all in one waterproof plug-in connector. (Female #9509)
Multiple AutoAnchor Installations
: T-adapters (#9506) and 2m/6.56 ft extension cables
with plugs (#9505) are available. Refer to the wiring diagrams for detail.
14
WIRING DIAGRAMS FOR AA702 BASE STATION
The following diagrams are included in the kit. Please refer to them for wiring detail.
702.1
Chain Only Windlasses
702.2
Rope/Chain Windlasses
702.3
AC and Hydraulic Windlasses
702.4
Bow Thruster with Windlass
702.5
Bow and Stern Thruster
All Chain Wiring for Multiple AutoAnchor Products
Rope and Chain Wiring for Multiple AutoAnchor Products
MOTOR LOAD WIRES (BROWN AND WHITE)
All-chain Counting:
If the AA710 is fitted to an
all-chain windlass or a thruster
the
brown and white wires are not connected.
Rope/chain Counting:
The brown and white wires must be connected for rope/chain
counting and for high current foot switches. These wires are connected direct to the
windlass motor terminals to measure the load on the motor.
A 1000 Ohm resister must
be fitted near the motor terminal
for short circuit protection. The motor load terminators
supplied in the kit have motor terminal connectors with a 1000 Ohm resister prefitted.