background image

RF-502

 

 

8

 

4.  Turn the ignition switch "ON/OFF", "ON/OFF". The siren will chirp 

one (1) time. You are now in the programming mode. 

 

 

5.  Press the ON/OFF button on one of the remote transmitters until the 

alarm siren responds with a confirming chirp. The first transmitter is 
now programmed. 

 

 

 

Within five (5) seconds

, press the ON/OFF button on the second 

transmitter until the alarm siren responds with a confirming chirp. 
The second transmitter is now programmed. 

NOTE

:

 If the RF-502 

does not receive a second code to learn within five (5) seconds, it 
will automatically close the programming mode and resume normal 
alarm functions

. If this happens, it will be necessary to repeat steps 

1 through 6 and re-program 

all

 transmitters.  If three or four 

transmitters are programmed, continue pressing the ON/OFF 
button of the third and/or fourth transmitters. 

 

 

6.  The RF-502 can learn up to four remote transmitter codes. If later 

optional third and forth transmitters are to be programmed, follow 
sequence 1 through 6 and re-program 

all

 existing transmitters. 

 

L.   

PROGRAMMING REMOTE FOR SECOND VEHICLES 

 
The RF-502 transmitters are capable of controlling separately installed 
RF-502 or RF-302 alarm systems in two or three vehicles. 
 
To code the RF-502 transmitters for two or three vehicles follow the 
diagrams as shown below. Before multiple vehicle programming can be 
achieved, it is necessary to enter the programming mode as described 
in SECTION K. 
 

1. TWO VEHICLE OPERATION 

 
VEHICLE #1 
 

Summary of Contents for RF-502

Page 1: ...RF 502 OPERATION INSTRUCTIONS...

Page 2: ...lue to their customers We sincerely hope the purchase of the RF 502 vehicle security system provides peace of mind to you Please take the time to read over this operation manual to thoroughly familiar...

Page 3: ...the lights will flash and all doors will unlock NOTE Your vehicle must be equipped with power door locks and optional relays may be required to allow alarm control over the vehicle door locks Additio...

Page 4: ...third violation within 15 seconds The RF 502 also provides a pre warnng sensor input for an additional sensor like a radar sensor to pre warn approach to the vehicle To delete the pre warning sensor...

Page 5: ...rm B LED STATUS INDICATOR OPERATION 1 LED OFF The RF 502 is disarmed 2 LED CONSTANT ON Indicates open trigger circuit 3 LED FAST FLASHING Passive arming timer is counting down 4 LED FLASHING The RF 50...

Page 6: ...T FUNCTION The RF 502 may be placed into the VALET stand by mode to allow for vehicle service car washing or attendant parking without self arming after the ignition is switched off and without leavin...

Page 7: ...se the exit and the LED will start flashing again 5 The RF 502 will count down for 30 seconds After 30 seconds the siren will chirp 1 time indicating the RF 502 has armed NOTE If the optional remote p...

Page 8: ...ter If a breach has occurred the siren will signal with 4 chirps the lights will flash four times and the LED will be flashing in a 2 second flash hold sequence I IGNITION CONTROL POWER DOOR LOCK SYST...

Page 9: ...ntinues the alarm will sound and lights will flash for two 60 second cycles K PROGRAMMING THE REMOTE TRANSMITTERS NOTE Each time the programming mode is entered all programmed transmitter codes will b...

Page 10: ...s it will be necessary to repeat steps 1 through 6 and re program all transmitters If three or four transmitters are programmed continue pressing the ON OFF button of the third and or fourth transmitt...

Page 11: ...the AUX button on the first transmitter used for Vehicle 1 The alarm siren will respond with a confirming chirp Within five 5 seconds push the ON OFF button on the second transmitter that had been pre...

Page 12: ...ly reliable electronic glass shock sensor the SIS 3 can be finely adjusted for each installation from sports cars to trucks When properly adjusted it virtually eliminates false triggers typically caus...

Page 13: ...nserted into the door for attempted illegal entry into the vehicle the MSEN KIT sensors are designed to provide limited coverage to specific areas They should be used in conjunction with other AutoPag...

Page 14: ...water contrary to the AutoPage INSTRUCTION MANUAL Or if used with accessories not approved by AutoPage which may have contributed to the defect 3 The purchaser s remedies under this WARRANTY shall be...

Page 15: ...rwise for Any personal injury of any kind to the purchaser its employees or agents or anyone else whomsoever resulting directly or indirectly from the use or presence of the equipment or parts Consequ...

Page 16: ...______ ________________________ Your Name Please print Company Name __________________________ ________________________ Address Address __________________________ ________________________ City State Z...

Page 17: ...13 DATE SERVICE COMPLETED...

Page 18: ...1815 W 205th St 101 Torrance CA 90501 310 618 2002...

Reviews: