background image

22

3

CONGRATULATIONS!  

You have purchased Auto Meter’s XTC-160OZR system 

designed to load test a battery and automatically provide a fast charge 

when needed. The system is fully automated with LCD readout for 

menu instructions, test results, and LED lights for unattended distance 

viewing. If you should have any questions about this equipment or the 

procedures, please see the back cover for contact information. 

XTC-160OZR

Tests  .........................  6 Volt and 12 Volt Battery Check and Load Test 

Load Sequence ............................Automated 160 Amp resistive ribbon 

Charge Sequence ......5 to 30 min. (larger discharged batteries longer) 

CCA Range.........................................................................  100 – 1600 

LCD ..........................................  Backlit 1" x 2.5" 4 line x 16 characters 

Cooling ...........................................................................5" Internal Fan 

Battery Temperature Measurement ................................... Infrared (IR) 

Temperature Probe Holder ......................  Mounts to Battery Enclosure

Leads ....................................Load Amp/Volt – 4 ft., 6 Gauge/18 Gauge 

2 conductor Smart Clamp 

Power Cord.....................................................................14 AWG 15 Ft. 

Size ......................................................................... 11.5" x 11" x 9 1/4" 

Weight .......................................................................................43.5 lbs 

T#10 12V BATT.

BATT. OVERHEATED

'Y' TO CONTINUE

T#10 12V BATT.

ERROR:ABORTED!

'Y' TO CONTINUE

The battery overheated during the 

charge. Let the battery cool and try 

recharging.

The charge stopped due to a hardware 

issue with the XTC-160. Check the 

clamps and AC power. Cycle the power 

on the XTC-160 and try a recharge. If 

error occurs again, call 866-883-8378 for 

technical assistance.

Summary of Contents for XTC-160OZR

Page 1: ...0OZR is the ultimate load tester and battery charger with fast and accurate automated testing and charging for the professional 2650 1741 00 10 8 13 T est Equipment Auto Meter Products Inc 413 West El...

Page 2: ...eads the voltage and the other jaw connects to the larger conducting wire that draws the load in each test Electrical isolation between jaws is necessary for accurate readings For side terminal batter...

Page 3: ...ce 5 to 30 min larger discharged batteries longer CCA Range 100 1600 LCD Backlit 1 x 2 5 4 line x 16 characters Cooling 5 Internal Fan Battery Temperature Measurement Infrared IR Temperature Probe Hol...

Page 4: ...terminals of any corrosion Clean clamps Battery is so discharged it is drawing more current than the XTC 160 can safely provide Place battery on a slow charger There is a problem with the AC power Bro...

Page 5: ...trolytic fluid and corrosion on battery connections can greatly reduce battery life and affect battery performance Age of Battery If the date code on the battery indicates it is fairly old the failure...

Page 6: ...spect Battery for terminal corrosion loose or broken posts cracks in the case moisture and dirt around the terminals Important Note A damaged battery must be replaced before proceeding From the menu s...

Page 7: ...e maximum time remaining to bring the battery to a full charge The LCD screen makes it possible to view the XTC 160OZR testing and charging status fully unattended The LCD provides easy menu instructi...

Page 8: ...screens will be displayed Battery passes testing Return to service Charge battery and place into service Test Only Battery did not have a sufficient charge for a Digital Pulse Load Test Charge require...

Page 9: ...NECTIONS CHECK BATTERY CONNECTIONS Y TO CONTINUE Adjust the rating using the Up and Down keys Press Y to Enter and begin the test If OTHER brand was selected the battery rating type is needed Use the...

Page 10: ...TO CHARGE SAFELY Y TO CONTINUE TEST CHARGE TEST ONLY CHARGE ONLY REVIEW PRINT The unit will go back to main menu Use the Up and Down keys to move the cursor The options are Super Start Optima and Othe...

Page 11: ...ttery categories the battery type is needed Use the Up or Down keys move the cursor Press Y to select Press N to go back to the Battery Category screen For marine batteries the battery function type i...

Page 12: ...TIME 10 MIN N TO STOP If the battery temperature goes over 140 F charging will stop If no temperature probe is connected use the Up and Down keys to enter the current battery temp The Up Down keys in...