22
The BCT-460DTNA
will instruct the user
to rev the engine to
governor speed and
hold it there.
The results of
the test will be
displayed. Any
failure will be
highlighted in red.
If the alternator fails due to
high voltage regulation and it
has remote sense the BCT-
460 DNTA will instruct the
user to disconnect the remote
sense wire and repeat the
governor speed test.
It the alternator fails for low
voltage regulations high ripple
voltage, or low output current, the
user will be directed to repair the
alternator
While the engine is
at governor speed
the unit will look
for low and high
regulation and
measure the output
current and the
ripple.
When the test
is complete the
BCT-460DTNA
will instruct the
user to return to
idle. If loads were
requested to turn
on, this screen will
remind the user to
turn them off.
POWERNET (ALTERNATOR TEST)