![auto maskin 1006472 User Manual Download Page 18](http://html1.mh-extra.com/html/auto-maskin/1006472/1006472_user-manual_3020687018.webp)
5.4.1 Active Station
There may be several RP panels in the network, all controlling the same engine.
Only one remote panel can be in control of the engine at any given time.
The Active Station dialog displays the connected engine this RP.
If there is a yellow star in the top-right position of the icon, as in the picture above, then
this
RP is currently in control of that engine.
Request the Active Station status
If the RP is not the active station for the engine, send a request to the RP with the current
active station status.
Select the engine and then select
Request
.
If there is only one RP in the network, it may initially not be the active station.
Select it once to store current selection (this will be valid also after reboot).
Release the Active Station status
The RP can release its Active Station status and make the engine “free” or available on the
network.
Other RP panels with lower priority settings than this RP can now become the active station
for that engine.
Select the engine, and then press the
Release
button.
5.4.2 Settings
This chapter describes the menu icons that are not found on the DCU 210E only.
Page 18 (20)