Wiring guidellines

-   The cables should be run separately from the mains connections and mains cables to 
  ensure good EMC conditions.
-   The LED wiring should be kept as short as possible to ensure good EMC.
  The max. secondary cable length is 2 m (4 m circuit), this applies for LED output as well 
  as for I-select 2.
-   Secondary switching is not permitted.
-   The LED Driver  has no inverse-polarity protection on the secondary side. Wrong polarity can  

  damage LED modules with no inverse-polarity protection.
-  Wrong wiring of the LED Driver can lead to malfunction or irreparable damage.

Hot plug-in

Hot plug-in is not supported due to residual output voltage of > 0 V.
If a LED load is connected the device has to be restarted before the output will be activated 

again.

This can be done via mains reset or via interface (DALI, DSI, switchDIM,
ready2mains).

Earth connection

The earth connection is conducted as protection earth (PE). The LED Driver
can be earthed via earth terminal. If the LED Driver will be earthed, protection earth (PE) 
has to be used. There is no earth connection required for the functionality of the LED Driver. 
Earth connection is recommended to improve following behaviour:

• Electromagnetic interferences (EMI)
• LED glowing at standby
• Transmission of mains transients to the LED output

In general it is recommended to earth the LED Driver if the LED module is mounted on earthed 

luminaire parts respectively heat sinks and thereby representing a high capacity against earth.

Summary of Contents for NT-810-154

Page 1: ...Description 2 Specifications 1 Dimmable constant curred LED driver 2 Dimming range from 1 100 3 Dimmig and switching on and off of the LEDs by means of DALI signal or commercail available buttons pus...

Page 2: ...5 mm of insulation from the cables to ensure perfect operation of the push wire terminals Use one wire for each terminal connector only Use each strain relief channel for one cable only 6 Installatio...

Page 3: ...voltage of 0 V If a LED load is connected the device has to be restarted before the output will be activated again This can be done via mains reset or via interface DALI DSI switchDIM ready2mains Ear...

Page 4: ...operating conditions Special attention needs to be paid at dimming and DC emergency operation as the forward voltage of the connected LED modules varies with the dimming level due to the implemented...

Page 5: ...Depending on the selected output current 3 Depending on the DALI traffic at the interface 4 The table only lists a number of possible operating points but does not cover each single point The output...

Page 6: ...igital control with DSI signal 8 bit Manchester Code Speed 1 to 100 in 1 4 s DALI signal 16 Bit Manchester Code Speed 1 to 100 in 0 2 s Programmable parameter Minimum dimming level 1 Programmable rang...

Page 7: ...to the mains signal which is wired to the mains terminal L and N switchDIM Integrated switchDIM function allows a direct connection of a pushbutton for dimming and switching Brief push 0 6 s switches...

Page 8: ...n 3 ready2mains Adjustment is done by the ready2mains programmer and the corresponding configuration software see ready2mains documentation The priority for current adjustment methods is DALI highest...

Page 9: ...er is protected against temporary thermal overheating If the temperature limit is exceeded the output current of the LED module s is reduced The temperature protection is activated approx 5 C above tc...

Page 10: ...The LED Driver adjusts the current afterwards automatically Power up down Fading The power up down function offers the opportunity to modify the on off behavior The time for fading on or off can be ad...

Page 11: ...PowerOnLevel DC level etc For further information see masterCONFIGURATOR manual 10 Miscellaneous Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage...

Page 12: ...etween plug in resistors are required Der Ausgangsstrom kann mittels Einsteckwiderst nden Programmierger t oder DALI eingestellt werden Wird kein Widerstand oder Drahtbr cke zwischen den I SELECT Ansc...

Reviews: