switchDIM and corridorFUNCTION are very simple tools for controlling gears with conventional 
pushbuttons or motion sensors.

To ensure correct operation a sinusoidal mains voltage with a frequency of 50 Hz or 60 Hz 
is required at the control input.

Special attention must be paid to achieving clear zero crossings. 
Serious mains faults may impair the operation of switchDIM and corridorFUNCTION.

Constant light output (CLO)

The luminous flux of a LED decreases constantly over the life-time. The CLO function ensures 
that the emitted luminous flux remains stable. For that purpose the LED current will increase 
continuously over the LED life-time.

In masterCONFIGURATOR it is possible to select a start value (in percent) and an expected 
life-time. The LED Driver adjusts the current afterwards automatically.

Power-up/-down Fading

The power-up/-down function offers the opportunity to modify the on-/off behavior. 
The time for fading on or off can be adjusted in a range of 0.2 to 16 seconds. 
According to this value, the device dims either from 0 % up to the power-on level or from the 
current set dim level down to 0 %.

This feature applies while operating via switchDIM, ready2mains and when switching the mains 

voltage on or off. By factory default no fading time is set (= 0 seconds).

Light level in DC operation

The LED Driver is designed to operate on DC voltage and pulsed DC voltage.
For a reliable operation, make sure that also in DC emergency operation the LED Driver is 
run within the specified conditions as stated in chapter “4.1 operating window”.

Light output level in DC operation: programmable 1 – 100 % (EOFi = 0.13).
Programming by DALI or ready2mains.

In DC operation dimming mode can be activated.

Summary of Contents for NT-810-154

Page 1: ...Description 2 Specifications 1 Dimmable constant curred LED driver 2 Dimming range from 1 100 3 Dimmig and switching on and off of the LEDs by means of DALI signal or commercail available buttons pus...

Page 2: ...5 mm of insulation from the cables to ensure perfect operation of the push wire terminals Use one wire for each terminal connector only Use each strain relief channel for one cable only 6 Installatio...

Page 3: ...voltage of 0 V If a LED load is connected the device has to be restarted before the output will be activated again This can be done via mains reset or via interface DALI DSI switchDIM ready2mains Ear...

Page 4: ...operating conditions Special attention needs to be paid at dimming and DC emergency operation as the forward voltage of the connected LED modules varies with the dimming level due to the implemented...

Page 5: ...Depending on the selected output current 3 Depending on the DALI traffic at the interface 4 The table only lists a number of possible operating points but does not cover each single point The output...

Page 6: ...igital control with DSI signal 8 bit Manchester Code Speed 1 to 100 in 1 4 s DALI signal 16 Bit Manchester Code Speed 1 to 100 in 0 2 s Programmable parameter Minimum dimming level 1 Programmable rang...

Page 7: ...to the mains signal which is wired to the mains terminal L and N switchDIM Integrated switchDIM function allows a direct connection of a pushbutton for dimming and switching Brief push 0 6 s switches...

Page 8: ...n 3 ready2mains Adjustment is done by the ready2mains programmer and the corresponding configuration software see ready2mains documentation The priority for current adjustment methods is DALI highest...

Page 9: ...er is protected against temporary thermal overheating If the temperature limit is exceeded the output current of the LED module s is reduced The temperature protection is activated approx 5 C above tc...

Page 10: ...The LED Driver adjusts the current afterwards automatically Power up down Fading The power up down function offers the opportunity to modify the on off behavior The time for fading on or off can be ad...

Page 11: ...PowerOnLevel DC level etc For further information see masterCONFIGURATOR manual 10 Miscellaneous Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage...

Page 12: ...etween plug in resistors are required Der Ausgangsstrom kann mittels Einsteckwiderst nden Programmierger t oder DALI eingestellt werden Wird kein Widerstand oder Drahtbr cke zwischen den I SELECT Ansc...