Malfunctions

9

LIAIREA0-01

3 Malfunctions

Use the light signals shown by the A8 unit during recharging to identify possible malfunctions.

If the problem persists after the suggested solution has been carried out, contact the support 

service of the machine manufacturer.

LeD

signals

Possible reason

solutions

G

reen

On at the end of 

charge, but the 

battery endurance is 

significantly shorter 

than normal

Exhausted battery.

Replace the battery with a 
charged and working one.

r

ed

On after recharging 

for approximately 4h

Faulty battery

Replace the battery with a 
charged and working one.

On with weak 

luminous intensity

b

Dirty contacts on the 
transmitting unit and/or on the 
docking station.

Clean the contacts on the 
transmitting unit and on the 
docking station with a non-
abrasive cloth or brush and 
a generic electrical contact 
cleaner.

Switched off

AC/DC power supply unit 
is damaged or not correctly 
powered.

Check that the AC/DC power 
supply unit is intact, well 
connected to the plug and 
correctly powered (see power 
supply unit's technical data 
plate).

Faulty docking station.

Replace the docking station 
with a working one.

Faulty transmitting 
unit

Replace the transmitting unit 
with a working one.

Faulty battery

Replace the battery with a 
working one.

b.  This signal appears if the A8 unit is in the docking station with the STOP pushbutton activated, 

and when you press the START pushbutton the luminous intensity significantly increases.

Summary of Contents for AIRBM3V7L

Page 1: ...2 1 2 Plate 2 1 3 Warnings for battery usage 3 1 4 First aid 3 1 5 Instructions for use 3 1 6 Storage 4 1 7 Battery disposal 5 2 Docking station AIRDOCK01 6 2 1 Connecting the docking station and the...

Page 2: ...3 7V 1300mAh Max recharge time 4h Recharge temperature 5 C to 45 C 41 F to 113 F Usage temperature 20 C to 55 C 4 F to 131 F Storage temperature 20 C to 60 C 4 F to 140 F a a Valid for a storage time...

Page 3: ...examples of improper use short circuit the battery poles disassemble cut open press deform drill modify tamper with batteries or attempt to repair them in any way try to insert objects in the batterie...

Page 4: ...ty loss If you expect not to use the battery for a long time it is recommended to store it in a cool and dry place in order to ensure its maximum lifetime The following table shows the residual batter...

Page 5: ...eries Users participation in the collection and recycling of batteries is important to reduce to the minimum any potential impacts of substances used in these components on the environment and on huma...

Page 6: ...through the docking station AIRDOCK01 and its adapter wall mounted FRA012 S05 or car mounted CLA05D 050A provided by Autec together with the radio remote control Use of a docking station and a power s...

Page 7: ...mains adapter with soaked or wet hands or feet or using objects tools and or instruments that conduct electricity are not insulated or are not protected from the risk of electrical shock do not in an...

Page 8: ...mage that may result from improper incorrect or irrational use of the docking station and of the power supply unit 2 3 1 Charged First power on the docking station with its power supply unit and then...

Page 9: ...sityb Dirty contacts on the transmitting unit and or on the docking station Clean the contacts on the transmitting unit and on the docking station with a non abrasive cloth or brush and a generic elec...

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: