AUTEC - Air series
Malfunctions
9
LIAIREA0-01
3 Malfunctions
Use the light signals shown by the A8 unit during recharging to identify possible malfunctions.
If the problem persists after the suggested solution has been carried out, contact the support
service of the machine manufacturer.
LeD
signals
Possible reason
solutions
G
reen
On at the end of
charge, but the
battery endurance is
significantly shorter
than normal
Exhausted battery.
Replace the battery with a
charged and working one.
r
ed
On after recharging
for approximately 4h
Faulty battery
Replace the battery with a
charged and working one.
On with weak
luminous intensity
b
Dirty contacts on the
transmitting unit and/or on the
docking station.
Clean the contacts on the
transmitting unit and on the
docking station with a non-
abrasive cloth or brush and
a generic electrical contact
cleaner.
Switched off
AC/DC power supply unit
is damaged or not correctly
powered.
Check that the AC/DC power
supply unit is intact, well
connected to the plug and
correctly powered (see power
supply unit's technical data
plate).
Faulty docking station.
Replace the docking station
with a working one.
Faulty transmitting
unit
Replace the transmitting unit
with a working one.
Faulty battery
Replace the battery with a
working one.
b. This signal appears if the A8 unit is in the docking station with the STOP pushbutton activated,
and when you press the START pushbutton the luminous intensity significantly increases.