Autarco S2.GPRS-BOX Installation Manual Download Page 2

 

 

 

 

2   

         

GPRS Monitoring Gateway 

 

 

 

 

 

 

 

 

Contact Information 

 

Autarco Group B.V. 

Schansoord 60 

5469 DT Erp 

The Netherlands 

 

www.autarco.com 

[email protected] 

 

 

 

Other Information 

 

This manual is an integral part of the unit. Please read the manual carefully before installation, operation or 

maintenance. Keep this manual for future reference. 

 

Product information is subject to change without notice. All trademarks are recognized as the property of their 

respective owners. 

 

If any technical problems occur, please contact us with the following information in hand. 

-

 

Device Model 

-

 

Serial number of product 

 

© Autarco Group B.V. 

All rights reserved. 

 

 

 

Summary of Contents for S2.GPRS-BOX

Page 1: ...Autarco Group B V IM S2 GPRS GATEWAY EN V1 0 Installation manual GPRS Monitoring Gateway for Autarco inverters...

Page 2: ...se read the manual carefully before installation operation or maintenance Keep this manual for future reference Product information is subject to change without notice All trademarks are recognized as...

Page 3: ...nitoring Gateway 6 2 1 Connection with single inverter 6 2 2 Connection with multiple inverters 7 2 3 Confirm connection 7 3 Setting up the SIM card 8 3 1 Unlock the security code on your SIM card 8 3...

Page 4: ...tructions WARNING Indicates safety instruction which if not correctly followed can result in injury or property damages The GPRS Monitoring Gateway can collect information of PV systems by GPRS commun...

Page 5: ...wise It should at all times be installed indoors WARNING When you screw unscrew or adjust the antenna please make sure that you only use the metal part of the antenna Do not hold the plastic part whil...

Page 6: ...t inverter to gateway with monitoring cable and connect gateway to power supply with power adapter WARNING Power supply of inverters must be cut off before connection Make sure that all connections ar...

Page 7: ...and the third must be set as 03 and so on a On the inverter press ENTER and then UP DOWN to navigate to SETTINGS b Select SET ADDRESS c Set address and press ENTER to save d For further details pleas...

Page 8: ...nputting the current PIN code OK iPhone WARNING Most iPhones use a SIM card in the so called nano size If you would like to use an iPhone for this procedure you will have to make sure the SIM card is...

Page 9: ...low maximum bandwidth Some providers have a portal to manage multiple cards Please contact your provider for installation outside the Netherlands 4 Registration 4 1 Check connection in MyAutarco In M...

Page 10: ...nection between gateway and inverter is abnormal LINK On Gateway connected to server connection is normal Flashing Data is transmitting between gateway and server Off Connection between gateway and se...

Page 11: ...lashing GSM signal is too weak Move gateway or adjust the antenna to other position for better signal Antenna is loose Check if the antenna is loose if so please screw to tighten On X X O GSM signal i...

Reviews: