AS5000 Programmer GUI software 

4.1

 

Installing the GUI on the PC 

 
The preliminary software is developed for a Microsoft Windows XP operating system with Service Pack 2. In addition 
the dotnet (.NET) framework version 2.0 or more must be installed on the PC. This package can be downloaded free of 
charge from the Microsoft webpage: 

http://www.microsoft.com/downloads/details.aspx?FamilyID=0856eacb-4362-4b0d-8edd-aab15c5e04f5&displaylang=en

 

 
Following Procedure is recommended before starting the GUI: 
 

1.

 

check on your PC if Service Pack 2 is installed 

2.

 

install the mentioned .NET package to your computer 

3.

 

execute setup.exe 

4.

 

Finally start the GUI using the shortcut in the start menu or desktop. 

 

 

4.2

 

The Home tab 

Figure 4 shows the main window of the GUI. On the top left corner, board information’s as firmware (FW) version and 
demoboard name declaration can be found.  
By default the GUI is in the auto detection mode. Any connected austriamicrosystems demoboard and programming tool will 
be automatically detected and displayed in the right top corner. The GUI is divided into three main sections HOME, SSI and 
OTP. 
 
 

 

Figure 4: AS5000 GUI detected the AS5040 Demoboard

Device selection list: 
Change the encoder type if a different encoder type is 
connected externally on J6 and SW1 on left position 

Summary of Contents for AS5040

Page 1: ...with mounted magnet knob 3 Operating the AS5X40 Demoboard The AS5X40 demoboard can be used in several ways As standalone unit supplied by a 9V battery Connect a 9V battery to the battery connector on the top right side of the board No other connections are required As standalone unit supplied by an USB port Connect the demoboard to a PC using a USB USB cable included in demoboard shipment The boar...

Page 2: ... becomes longer and the OFF pulse becomes shorter Likewise the PWM output can be used as an analog output proportional to the angle when the PWM signal is filtered by a RC or active lowpass filter The PWM signal 0 3V3 can be directly taken from the connector J4 3 1 3 Incremental quadrature AB Index LED The phase shift between channel A and B indicates the direction of the magnet movement Channel A...

Page 3: ...ly to J6 In this configuration the data of the serial interface are displayed on the GUI or the LCD In standalone mode regardless to the demoboard type AS5040 or AS5140 AS5040 and AS5140 can be attached to J6 and evaluated See figure 3 If the GUI is used for operation additional devices AS5043 AS5143 AS5045 and AS5145 can be connected to J6 and evaluated In that case the correct encoder must be se...

Page 4: ... GUI 1 check on your PC if Service Pack 2 is installed 2 install the mentioned NET package to your computer 3 execute setup exe 4 Finally start the GUI using the shortcut in the start menu or desktop 4 2 The Home tab Figure 4 shows the main window of the GUI On the top left corner board information s as firmware FW version and demoboard name declaration can be found By default the GUI is in the au...

Page 5: ... into the Zero Position register Clicking on Reset writes the value 0 to the Zero Position register The Magnetic Range Warning is continuously read from the RD_ANGLE serial command Green lamp Magnet in range Orange lamp Magnet too far or too close MagINC and MagDEC are set The Status bits information are taken from the serial stream The Read Interval can be modified from 10 ms fastest to 1 s slowe...

Page 6: ... The button Write should be clicked to write the parameter into the AS5X40 The Read button reads back the OTP register and updates the Field parameter as well as the OTP bits window Figure 6 OTP tab Field Zero Position To zero position value like on the SSI tab The zero position value can be changed by checking the Z 0 9 bits or changing the Value field with a decimal number Field Pulses per Revol...

Page 7: ...n DS1 LED3 R6 1k GND J4 PWM R1 10k GND C3 100n GND 3V 3V GND 3V GND C16 1u 16V C15 1u 16V C14 1u 16V C13 1u 16V C12 1u 16V GND C8 1u 16V C10 1u 16V C11 1u 16V GND C9 1u 16V R2 nc C6 100n C7 100n 3V GND C2CK C2D C1 100n C5 1u GND P0 1 1 P0 0 2 P2 7 11 P2 6 12 P2 5 13 P2 4 14 P2 3 15 P2 2 16 P2 1 17 P2 0 18 P1 7 19 P1 6 20 P1 5 21 P1 4 22 P1 3 23 P1 2 24 P1 1 25 P1 0 26 P0 7 27 P0 6 28 P0 5 29 P0 4 ...

Page 8: ...AS5X40 Demoboard OPERATIONAL MANUAL Revision 1 0 29 Jan 2009 www austriamicrosystems com Page 8 of 12 Figure 9 AS5x40 Blockdiagramm ...

Page 9: ...e Indicators and Connectors 2 3 1 1 Graphic LCD display 2 3 1 2 PWM LED 2 3 1 3 Incremental quadrature AB Index LED 2 3 1 4 MagINCn and MagDECn 2 3 1 5 Encoder selection switch 3 4 AS5000 Programmer GUI software 4 4 1 Installing the GUI on the PC 4 4 2 The Home tab 4 4 3 The SSI tab 5 4 4 The OTP tab 6 5 AS5X40 Demoboard Schematics Blockdiagramm 7 Index 9 Revision History 10 Contact 11 Copyright 1...

Page 10: ...AS5X40 Demoboard OPERATIONAL MANUAL Revision 1 0 29 Jan 2009 www austriamicrosystems com Page 10 of 12 Revision History Revision Date Description R1 0 March 16 2009 First version ...

Page 11: ...G40 4ET United Kingdom Phone 44 118 973 1797 Fax 44 118 973 5117 austriamicrosystems AG Klaavuntie 9 G 55 FI 00910 Helsinki Finland Phone 358 9 72688 170 Fax 358 9 72688 171 austriamicrosystems AG Bivägen 3B S 19163 Sollentuna Sweden Phone 46 8 6231 710 austriamicrosystems USA Inc 8601 Six Forks Road Suite 400 Raleigh NC 27615 USA Phone 1 919 676 5292 Fax 1 509 696 2713 austriamicrosystems USA Inc...

Page 12: ...use in normal commercial applications Copyright 2009 austriamicrosystems Trademarks registered All rights reserved The material herein may not be reproduced adapted merged translated stored or used without the prior written consent of the copyright owner To the best of its knowledge austriamicrosystems asserts that the information contained in this publication is accurate and correct However austr...

Reviews: