f) Thought should be given to the selection or to the order of sequence of the installation materials that
are to be used with the equipment (take special care with mixed installations) in accordance with the
rules of engineering with respect to any possible electrochemical processes (contact corrosion, for
example in copper-steel). We recommend installing isolation screw fittings.
g) If there is particularly aggressive water, which requires special solutions in terms of the installation,
the possible need for special versions of the storage tank should be looked into (please make enqui-
ries with our representatives or directly with our company)..
h) The equipment is fitted with a safety temperature limiting device, which switches off any further
heating of the equipment upon reaching a maximum water temperature of 110°C. The selection of
the connecting components (connecting pipes safety valve combinations, etc.) should be carried
out in such a way that the connecting components, in the event of any possible malfunctioning of
the temperature control system, withstand temperatures of 110°C and avoid any consequential
damage.
i) The assembly and installation work may only be performed by duly authorised tradesmen.
9. Dimensional drawing
requirements
in litres
Type of design
dimensions in mm
weight kg
H
A
B
50
Suspended storage unit
569
130
350
30
80
Suspended storage unit
760
280
400
40
100
Suspended storage unit
884
280
600
47
120
Suspended storage unit
1019
280
600
54
150
Suspended storage unit
1219
280
800
64
Thin-wall suspension