SAFETY INSTRUCTIONS 

General

•  This tank can be used by children eight years old and older as well as by persons with reduced 

physical, sensory or mental capabilities or who lack experience and knowledge if they are super-
vised or if they have been trained with regard to the safe use of the tank and understand the resul-
ting risks. Children may not play with the tank or its packaging. Cleaning and user maintenance 
may not be performed by children without supervision.

•  The tank may only be installed and operated as described in this manual or the associated 

technical information. Any other use is not proper and is therefore impermissible.

•  A defective tank may not continue to be operated.
•  There is a risk of scalding from hot water or hot components (e.g. fittings, hot water outlet pipe, 

etc.).

•  When using an electric immersion heater, proper corrosion protection is to be ensured.

Installation and commissioning

•  Installation and commissioning may only be performed by qualified specialised personnel who 

therefore assume the responsibility for the proper assembly according to the applicable laws, 
standards and guidelines. 

•  The tank is mounted to a sufficient load-bearing wall using a wall mount (note the total weight of 

the filled tank) or is placed on a flat horizontal surface after mounting the included adjustable feet. 
Ensure that the subsurface at the installation location has a sufficient load-bearing capacity.

•  The tank may only be set up in dry, freeze-protected spaces. The tank is to be completely emp-

tied if there is a risk of freezing.

•  The rated pressure specified on the nameplate may not be exceeded.
•  When installing the tank, a possible water leak is to be considered and a corresponding collection 

container (including drain) is to be installed in a drainage object. 

•  Following the commissioning, the tank and all connections are to be checked for leak tightness.

Electrical Connection

•  Only qualified specialised personnel may connect the tank to fixed lines while observing the re-

levant professional standards and laws.

•  A ground fault circuit interrupter with a trip current of I

∆n

 ≤ 30mA must be installed upstream from 

the electrical circuit.

•  Before working on the tank, this is to be de-energised, checked for the absence of voltage and 

secured against being switched on again.

•  If a connection cable is damaged, immediately disconnect the power supply (circuit breaker) and 

call a professional!

•  Connection cables may not be extended or cut through in any way.

Servicing

•  Maintenance, cleaning and any necessary repair or service work may only be performed by spe-

cialised personnel who are qualified for this purpose.

•  Never try to fix errors and faults yourself.
•  Necessary service and maintenance intervals are to be observed in accordance with these ope-

rating and assembly instructions.

Summary of Contents for EKL 100

Page 1: ...eater with control panel of the series EKR Wall mounted storage tank with heat exchanger EKL Wall mounted storage tank horizontal Please pass to the user Id Nr 228843 16 Austria Email AG Austriastra e...

Page 2: ...ation foam the standby energy consumption is extraordinarily low The ARA license lets you return of packaging of your device which will then be disposed of expertly to avoid environmental damage Insta...

Page 3: ...ty information 8 Dimensioned drawing 9 Series EKR 9 Series EKL 10 Product fiche ErP 11 EKR 11 EKL 11 Service water connection pressure proof 12 Non pressure Connection 13 Central heating connection on...

Page 4: ...nting the included adjustable feet Ensure that the subsurface at the installation location has a sufficient load bearing capacity The tank may only be set up in dry freeze protected spaces The tank is...

Page 5: ...the insulation the piping and the individual user s habits The following table provides a list of standard consumption values for orientation In this table it was assumed that the temperature of the c...

Page 6: ...rs old and older as well as by persons with reduced physical sensory or mental capabilities or who lack experience and knowledge if they are supervised or if they have been trained with regard to the...

Page 7: ...s of the local electricity company and water supply works as well as the installation and operation instructions is required The room where the device is operated must be free of frost The device must...

Page 8: ...st be taken into account for load related and strength related design of the device mounting surface or selection of the mounting location Special suspensions see thin wall and or ceiling suspension f...

Page 9: ...ht in kg A A adbustable von bis C H B T EKR 100 100 H ngespeicher m Heizregister 600 400 700 300 921 520 520 66 EKR 120 120 H ngespeicher m Heizregister 800 550 800 300 1056 520 520 74 EKR 150 150 H n...

Page 10: ...storage tank 500 150 780 480 480 80 42 EKL 100 100 Horizontal storage tank 500 300 904 480 480 80 52 EKL 120 120 Horizontal storage tank 500 300 1056 520 520 100 61 EKL 150 150 Horizontal storage tank...

Page 11: ...e manual Refer to the manual Refer to the manual Comments EKL Modell EKL 80 EKL 100 EKL 120 EKL 150 EKL 200 Tank volume l 80 100 120 150 200 Mixed water volume V40 122 152 183 228 304 Load profile M M...

Page 12: ...must lead into the sewer so that neither frost nor clogging by dirt or anything similar may cause any malfunction Make sure that the drip cup is not blocked Furthermore it must be observed that the dr...

Page 13: ...t of an im proper connection and resulting damage and consequential damage are excluded from the warranty and product liability NON PRESSURE CONNECTION In cases in which fittings are used for non pres...

Page 14: ...h could damage the heat exchanger If the water heater is heated by its heat exchanger then it must be ensured that in no case the hot water temperature exceeds 85 C as otherwise the safety temperature...

Page 15: ...Storage tank content 100l kW A 1 10 6 1 75 10 2 20 10 2 85 16 2 80 6 Storage tank content 120l kW A 1 35 10 2 00 10 2 70 16 3 35 16 3 20 6 Storage tank content 150l kW A 1 65 10 2 30 16 3 30 16 3 70 1...

Page 16: ...1 3 hrs 3 1 3 hrs EKL 080 U 1 00 0 65 1 00 1 00 1 65 2 00 2 65 2 60 EKR 100 U EKL 100 U 1 10 0 65 1 10 1 10 1 75 2 20 2 85 2 80 EKL 120 U 1 30 0 65 1 30 1 30 1 95 2 60 3 25 3 10 EKR 120 U 1 35 0 65 1...

Page 17: ...Hot water may flow out during the draining procedure If there is a risk of frost do not forget that not only the water in the water heater and in the hot water lines may freeze but also in all cold wa...

Page 18: ...Do not damage or remove the protective current discharge re sistor underneath the heater fastening screw during maintenance work d Do not use abrasive cleaning agent and no paint thinners such as nit...

Page 19: ...as a consequence of aggressive waters water not suitable for drinking in accordance with the national regulations e g Austrian ordinance on drinking water TWV Fed Law Gazette II No 304 2001 deviation...

Page 20: ...andatory that for processing of the claim the necessary do cumentation such as the part number and manufacturing number of the water heater the seller s invoice and that of the executing license holde...

Reviews: