background image

Id.Nr.: 228843-16

19

WARRANTY, GUARANTEE AND PRODUCT LIABILITY

Warranty is made according to the legal provisions of the Republic of Austria and the EU.

1.   The prerequisite for honoring of warranty terms on the part of the manufacturer (hereinafter referred to as Manu-

facturer) is presentation of a paid invoice for the purchase of the appliance in question, whereby the identity of the 
appliance including model and fabrication number must be indicated on the invoice and presented by the claim 
applicant. The General Terms and Conditions, Terms and Conditions of Sale and Delivery of the manufacturer shall 
apply exclusively.

2.   The assembly, installation, wiring and startup of the appliance in question must, to the extent that this is prescribed 

legally or in the installation and operation guide, have been performed by an authorized electrical technician or 
installer who has followed all the required regulations. The hot water tank (excluding outer jacket or plastic cover) 
must be protected from exposure to direct sunlight to prevent discoloration of the polyurethane foam and possible 
cracking of plastic parts.

3.   The area in which the appliance is operated must be kept from freezing. The unit must be installed in a location 

where it can be easily accessed for maintenance, repair and possible replacement. The costs for any necessary 
changes to the structural conditions (e.g. doors and passages too narrow) are not governed by the guarantee and 
warranty declaration and therefore shall be rejected on the side of manufacturer. When erecting, installing and 
operating the water heater in unusual locations (e.g. attics, interior rooms with water-sensitive floors, closets, etc.), 
provision must be made for possible water leakage and means provided for catching the water with a correspon-
ding drain to avoid secondary damage in the context of product liability.

4.   Warranty claims will not be honored for:
 

inappropriate transport, normal wear and tear, intentional or negligent damage, use of force of any kind or descrip-
tion, mechanical damage or damage caused by frost or also by exceeding the operating pressure stated on the 
rating plate, even if only once, use of connection fittings that do not comply with the standard, use of defective 
tank connection fittings and unsuitable and defective service fittings. Breaking of glass and plastic components, 
possible colour differences, damage due to improper use, in particular non-observance of the mounting and ope-
rating instructions (Operating and Mounting Instructions), damage by external influence, connecting to incorrect 
voltage, corrosion damage as a consequence of aggressive waters (water not suitable for drinking) in accordance 
with the national regulations (e.g. Austrian ordinance on drinking water, TWV – Fed. Law Gazette II No. 304/2001), 
deviations between the actual drinking water temperature at the tank fitting and the specified hot water tempera-
ture of up to 10K (hysteresis of the controller and possible cooling due to pipelines), Continued use, despite the 
occurrence of a defect, unauthorised modifications to the device, installation of additional components that were 
not tested together with the device, improperly carried out repairs,  Insufficient water conductivity (min. 150 µs/cm) 
operational wear of the magnesium anode (wearing part), natural formation of boiler scale, lack of water, fire, flood, 
lightning, overvoltage, power failure or other types of force majeure. Use of non-original and company-external 
components such as e.g. heating elements, reactive anode, thermostat, thermometer, ribbed tube heat exchan-
ger, etc., Parts installed in an uninsulated condition with respect to the storage tank, ingress of foreign particles 
or electrochemical influences (e.g. mixed installations), failure to observe the design documents, unpunctual and 
undocumented renewal of the installed protective anode, no or improper cleaning and operation, as well as any 
deviations from the standard that reduce the value or functionality of the device only slightly. Fundamental compli-
ance with all regulations in ÖNORM B 2531, DIN 1988 (EN 806), DIN 1717, VDI 2035 or the corresponding national 
regulations and laws must be ensured.

5.   A justified claim must be reported to the closest customer service location of the manufacturer. The latter reserves 

the right to replace or repair a defective part or to decide whether a defective appliance shall be replaced with a 
working one of equal value. The manufacturer furthermore expressly reserves the right to require that the purchaser 
return the appliance in question.  The time of a repair or a replacement is determined by the production.

6.   Repairs made under warranty are to be performed only by persons authorized by the manufacturer. Replaced parts 

become the property of the manufacturer. If any repairs to the water heater become necessary as part of necessary 
service work, these are charged at the cost of repair and prorated material cost.

7.   Any work performed without our express order, even this is done by an authorized installer, will void the warranty. 

Assumption of the costs for repairs performed by third parties presumes that the manufacturer was requested to 
eliminate the defect and did not or did not in timely fashion meet his obligation for replacement or repair.

8.   The warranty period will not be renewed or extended as a result of a guarantee and warranty claim, service or 

maintenance work.

Summary of Contents for EKL 100

Page 1: ...eater with control panel of the series EKR Wall mounted storage tank with heat exchanger EKL Wall mounted storage tank horizontal Please pass to the user Id Nr 228843 16 Austria Email AG Austriastra e...

Page 2: ...ation foam the standby energy consumption is extraordinarily low The ARA license lets you return of packaging of your device which will then be disposed of expertly to avoid environmental damage Insta...

Page 3: ...ty information 8 Dimensioned drawing 9 Series EKR 9 Series EKL 10 Product fiche ErP 11 EKR 11 EKL 11 Service water connection pressure proof 12 Non pressure Connection 13 Central heating connection on...

Page 4: ...nting the included adjustable feet Ensure that the subsurface at the installation location has a sufficient load bearing capacity The tank may only be set up in dry freeze protected spaces The tank is...

Page 5: ...the insulation the piping and the individual user s habits The following table provides a list of standard consumption values for orientation In this table it was assumed that the temperature of the c...

Page 6: ...rs old and older as well as by persons with reduced physical sensory or mental capabilities or who lack experience and knowledge if they are supervised or if they have been trained with regard to the...

Page 7: ...s of the local electricity company and water supply works as well as the installation and operation instructions is required The room where the device is operated must be free of frost The device must...

Page 8: ...st be taken into account for load related and strength related design of the device mounting surface or selection of the mounting location Special suspensions see thin wall and or ceiling suspension f...

Page 9: ...ht in kg A A adbustable von bis C H B T EKR 100 100 H ngespeicher m Heizregister 600 400 700 300 921 520 520 66 EKR 120 120 H ngespeicher m Heizregister 800 550 800 300 1056 520 520 74 EKR 150 150 H n...

Page 10: ...storage tank 500 150 780 480 480 80 42 EKL 100 100 Horizontal storage tank 500 300 904 480 480 80 52 EKL 120 120 Horizontal storage tank 500 300 1056 520 520 100 61 EKL 150 150 Horizontal storage tank...

Page 11: ...e manual Refer to the manual Refer to the manual Comments EKL Modell EKL 80 EKL 100 EKL 120 EKL 150 EKL 200 Tank volume l 80 100 120 150 200 Mixed water volume V40 122 152 183 228 304 Load profile M M...

Page 12: ...must lead into the sewer so that neither frost nor clogging by dirt or anything similar may cause any malfunction Make sure that the drip cup is not blocked Furthermore it must be observed that the dr...

Page 13: ...t of an im proper connection and resulting damage and consequential damage are excluded from the warranty and product liability NON PRESSURE CONNECTION In cases in which fittings are used for non pres...

Page 14: ...h could damage the heat exchanger If the water heater is heated by its heat exchanger then it must be ensured that in no case the hot water temperature exceeds 85 C as otherwise the safety temperature...

Page 15: ...Storage tank content 100l kW A 1 10 6 1 75 10 2 20 10 2 85 16 2 80 6 Storage tank content 120l kW A 1 35 10 2 00 10 2 70 16 3 35 16 3 20 6 Storage tank content 150l kW A 1 65 10 2 30 16 3 30 16 3 70 1...

Page 16: ...1 3 hrs 3 1 3 hrs EKL 080 U 1 00 0 65 1 00 1 00 1 65 2 00 2 65 2 60 EKR 100 U EKL 100 U 1 10 0 65 1 10 1 10 1 75 2 20 2 85 2 80 EKL 120 U 1 30 0 65 1 30 1 30 1 95 2 60 3 25 3 10 EKR 120 U 1 35 0 65 1...

Page 17: ...Hot water may flow out during the draining procedure If there is a risk of frost do not forget that not only the water in the water heater and in the hot water lines may freeze but also in all cold wa...

Page 18: ...Do not damage or remove the protective current discharge re sistor underneath the heater fastening screw during maintenance work d Do not use abrasive cleaning agent and no paint thinners such as nit...

Page 19: ...as a consequence of aggressive waters water not suitable for drinking in accordance with the national regulations e g Austrian ordinance on drinking water TWV Fed Law Gazette II No 304 2001 deviation...

Page 20: ...andatory that for processing of the claim the necessary do cumentation such as the part number and manufacturing number of the water heater the seller s invoice and that of the executing license holde...