EN
23
THERMOMETER
There is a remote thermometer built into the front panel of the de-
vice for monitoring the stored water temperature.
The display value depends upon the temperature regulator setting.
Only with the adjustment knob at „Pos.
“ and after completion of
the warm up process is the maximum display value reached.
For other regulator positions the pointer deflection is reduced ac-
cordingly.
ADJUSTMENT RANGE LIMITATION
In order to avoid unintentional scalding caused by water
which is too hot, the adjustment range of the temperature
regulator can be limited to a maximum of 65°C. The device
must be electrically isolated from the grid at all poles. Set to
„Pos
“. After opening the connection space, remove the
stop pin in that is located in a drilling in the back of the con-
trol panel and reinsert it into the hole with the long shaft in
front.
OPERATING CONDITIONS
The tanks must be used exclusively in accordance with the conditions specified on the rating plate. The
maximum inlet pressure corresponds with the nominal pressure stated on the rating plate. Aside from
the legally approved national regulations and standards, the connecting requirements of the local power
company and waterworks, as well as the Mounting and Operating Instructions must be complied with.
The room in which the device is operated must be free of frost.
The device must be mounted at a location that may reasonably be expected, i.e. it must be possible to
access and replace the device without difficulties for the purpose of necessary maintenance, repairs and
possible replacement. The hot water tank must only be connected with permanent piping. In the case of
heavily calciferous water, we recommend the upstream integration of a customary anti-liming device or a
maximum operating temperature of approx. 65 °C (position
).
An appropriate quality (according to drinking water ordinance) of drinking water is required for proper ope-
ration. To avoid possible ingresses of particles, we recommend the upstream integration of a water filter.
Should a device, at the point of delivery, clearly display a malfunction, damage or other defect, this must
not be fitted, installed or used in the system. Subsequent complaints regarding devices with an obvious
defect which have been connected and installed are expressly excluded under the warranty and guaran-
tee.
Remote reading thermometer