Special functions
6.1.5. - 0-10V on / PWM on
This signal / this voltage is needed to turn the pump on at minimum speed / minimun
voltage.
Default setting: 90%
6.1.6. - 0-10V Max / PWM Max
This determines the output signal / the output voltage for the highest speed of the
pump, that is used e.g. during purging or manual operation.
6.1.7. - Show signal
Displays the set signal in text and a graphical diagram.
The settings in this menu are used to limit the speed of connected pumps.
6.2. - Speed control R1 / R2
Caution
Caution
The indicated percentages are guide values that may vary to a greater or
lesser extent depending on the system, pump and pump stage.
The indicated percentages are guide values that may vary to a greater or
lesser extent depending on the system, pump and pump stage.. 100% is
the maximum possible voltage/frequency of the controller.
6.2.1. - max. speed
6.2.2. - min. speed
The maximum speed of the pump is specified here. During the setting the pump runs
at the specified speed and the flow rate can be determined.
The minimum speed of the pump at relay R1 is specified here. During the setting the
pump runs at the specified speed and the flow rate can be determined.