Gate Open Delay / Close Delay Adjustment
Some double gates require a time delay in opening / closing to prevent the two gates clashing.
Determine which gate will need to open first & therefore close last. Typically, one or other of
the gates may be fitted with a ‘lip’ or ‘tab’ to help align the gates when closed. The lip or tab
may be fitted to the leading edge of the first-closing gate or the trailing edge of the last-closing
gate.
The motor (master motor or slave motor) of the first opening gate / last closing gate must be
connected to Motor 1 terminal.
Press and hold ‘OPN’
button to set required
delay time
.
Flick Dip Switch 1 to ‘ON’ to set
Motor M1 Terminals
First Opening Gate /
Last Closing Gate
Setting the Open delay / Close Delay Time
To set the gate delay time for the open delay / close delay flick DIP switch 1 to ‘ON’. Press and
hold down “OPN” button for the required open delay / close delay time you need and release the
button. For example if you want a 15 second open delay / close delay time then press and hold
down the “OPN” button for 15 seconds and release the button. Once open delay / close delay
time is set, flick DIP switch 1 back to OFF.
To
turn on
the open delay / close delay time, flick DIP switch 2 to ‘ON’ and leave it on. To
turn off
the open delay / close delay time function flick DIP switch 2 back to ‘OFF’.
Dip Switch 1
‘OFF’
Dip Switch 2 ‘ON’ to turn on open / close time delay
WARNING: Care should be taken as there are moving components inside the
gate motor that may cause damage or personal injury.
time. Flick back to off when finished