Gas Type and Gas Pressure 

  Do not use any other gas type except the one specified on the data label.  

For LP Gas Model (Supplied with regulator type 73-1-8 AGA 3884 and Hose TPA type APH801 6356) 

This model of appliance is suitable for use with LP gas and are set to operate under gas pressure of 2.75kPa. 
 

*The LP gas regulator and hose supplied are for outdoor installations only. Indoor installations must 
be installed in accordance with the requirements of AS/NZS5601.1. 
 
Indoor  installations  must  be  installed  in  accordance  with  the  requirements  of  AS/NZS5601.1,  Local 
State  and  Territory  regulations,  municipal  building  codes,  and  any  other  relevant  statutory 
regulations. 

 

For Natural Gas Model (Supplied with Bromic type 980L regulator AGA 5862) 

This model of appliance is only suitable for use with natural gas and are set to operate under gas pressure of 
0.90kPa. 

WARNING! It is hazardous to attempt to use other types of gas with this appliance. 
 
The Gas Inlet is located for model Y028NGWF-S/Y028LPWF-S 300mm up from the base and 25mm in 
from the RH side leg. For model Y018NGWF-S/Y018LPWF-S the gas inlet is located 260mm up from 
the base and in line with the RH leg side. 
Gas Cylinder (For LP Gas Model only) 

Only  cylinders  which  comply  with  AS2030.1  should  be  used.  The  appliance  is  suitable  for  use  with  gas 
cylinders of 3.9 kg or greater.  
The gas cylinder should not be dropped or handled roughly!  If the appliance is not in use, the cylinder must 
be disconnected.  Replace the protective cap on the cylinder after disconnecting the cylinder from the stove.  

WARNING! It may hazardous to use a damaged or dented gas cylinder. 

Cylinders must be stored outdoors in an upright position and out of the reach of children.  The cylinder must 
never be stored under direct sunlight or where temperatures can reach over 50

C.  Do not store the cylinder 

near flames, pilot lights or other sources of ignition.  DO NOT SMOKE around the cylinders. 

WARNING! It may hazardous to store gas cylinder in an enclosed place. 
 
Exchanging of the gas cylinder 

Ensure the valve on the cylinder is closed. Remove the hose assembly. Connect in reverse order and check 
for gas leakage at all joints with soapy water. 

 
Gas Hose Assembly 

Use  only  the  hose  assembly  supplied  with  the  appliance.  Use  only  a  gas  hose  that  complies  with 
AS/NZS1869.  The appliance requires a ‘Class B’ Gas hose.   The  hose  should  be secured to the regulator 
and  the  appliance  with  spanner.  Use  the  hose  with  the  right  threads,  DO  NOT  use  adaptors.  Inspect  the 
hose assembly before each use of the appliance. 
The life expectancy of the hose is estimated at 5 years.  It is recommended that the hose is changed every 5 
years. 
The  use  of  the  wrong  hose  is  unsafe.  Always  check  that  you  have  the  correct  items  before  operating  the 
appliance. 

WARNING! It may hazardous to use the wrong type of hose. 

 The length of the hose must not excess 1.8 metres (maximum). Worn or damaged hose must be replaced if 
there  is  evidence  of  excessive  abrasion  or  wear.    A  replacement  hose  is  supplied  by  Austcrown,  refer  to 
contact  detail.  Ensure  that  the  hose  is  not  obstructed,  kinked,  or  in  contact  with  any  part  of  the  appliance 
other than at its connection.  

WARNING! It may hazardous to use a damaged hose. 

 

Regulator

 

Use only the gas regulator supplied with the appliance which complies with AS4618. The appliance must be 
used with a LOW pressure regulator with output pressure of 2.75kPa for LP gas and 0.90kPa for Natural Gas. 
Use a regulator with the right threads.  
 

For Propane Gas Model:  
AUSCROWN TPA7010 AGA 5212 
Outlet Pressure: 2.75kPa 
Flow Capacity: 3kg/hr  
Inlet Fitting: CGA-510 POL with Soft Nose 
Outlet Fitting: 3/8” BSPF Thread 

For Natural Gas Model: Bromic 980L, AGA 5862 
Outlet Pressure: 0.90kPa 
Flow Capacity:  2 M

3

/hr (For Y018NGWF-S) 

Flow Capacity:

  3 M

3

/hr (For Y028NGWF-S) 

Inlet Fitting: ½” BSPF Thread 
Outlet Fitting: ½” BSPF Thread 

Summary of Contents for Y018LPWF-S

Page 1: ... the appliance is used especially following disconnection and reconnection of the cylinder NEVER CHECK FOR LEAKS WITH A MATCH OR OPEN FLAME DO NOT STORE OR USE PETROLEUM PRODUCTS OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS APPLIANCE AN LP CYLINDER NOT CONNECTED FOR USE IN THIS APPLIANCE SHALL NOT BE STORED NEAR THIS APPLIANCE TO BE INSTALLED ON A FIREPROOF BASE ONLY FOR YOUR SAF...

Page 2: ...n this appliance shall not be stored near this appliance Ensure the gas hose is not placed under the appliance or allowed to contact any hot surfaces of the appliance This appliance must not be modified or changed in any way Disconnect the gas cylinder from the burner prior to storage It is also recommended that the gas cylinder be stored outdoors in a well ventilated area Do not use any other gas...

Page 3: ...ors Do not use any naked flame or other ignition source such as light switches power points mobile phones and pagers Do not operate any electrical equipment in the vicinity of a gas leak Contact your licensed gas fitter to repair the leak and re light the appliance NEVER attempt to repair the appliance yourself IT MUST BE SERVICED BY AN AUTHORIZED PERSON PART INDEX 1 Burner 2 Safety Switch A 3 Pie...

Page 4: ...ings and to facilitate cleaning The appliance must be used on a level stable non flammable surface when in use This appliance is intended for commercial use only It is important that the ventilation openings of the appliance are not obstructed The appliance should be protected from direct draughts The appliance should not be positioned or protected against direct penetration by any trickling water...

Page 5: ...al enclosure that includes an overhead cover and more than two walls the following shall apply One wall that is equivalent to at least 25 of the total wall area is completely open see figure 4 Fig 4 30 or more in total of the remaining wall area is open and unrestricted see figure 5 In case of balconies at least 20 of the total of the side back and front wall areas shall remain open and unrestrict...

Page 6: ...er 50 C Do not store the cylinder near flames pilot lights or other sources of ignition DO NOT SMOKE around the cylinders WARNING It may hazardous to store gas cylinder in an enclosed place Exchanging of the gas cylinder Ensure the valve on the cylinder is closed Remove the hose assembly Connect in reverse order and check for gas leakage at all joints with soapy water Gas Hose Assembly Use only th...

Page 7: ...rdance to Australia Standard If a flexible hose is to be used DO NOT assemble beneath the appliance under direct sunlight or close to other sources of heat 6 The length of connection between the appliance and the main gas supply should not exceed 1 8m 7 Check for gas leakage at all joints with soapy water or other approved methods UNDER NO CIRCUMSTANCES SHOULD A NAKED FLAME BE USED IN CHECKING FOR...

Page 8: ...on service agent perform all maintenance If the burner fails to operate correctly contact place of purchase or authorised agent for advice and service RECOMMENDED POT SIZE Y018 Series Minimum Ø44cm Maximum Ø49cm Y028 Series Minimum Ø44cm Maximum Ø61cm CAUTION ...

Page 9: ...or assembly is required please contact place of purchase or authorized service agent for advice TROUBLESHOOTING DO NOT MODIFY THIS APPLIANCE If the appliance cannot be adjusted to perform correctly contact after sales service contact details this page Problem Possible Cause Solution No Ignition Main Gas Valve is not turned on Air trapped in the gas hose The safety valve is not open Turn off the ga...

Page 10: ...vanised supply pipe is disengaged from the galvanised elbow Remove the burner galvanised supply pipe Remove the burner by unscrewing centrally located 10mm hex screws Note the pilot and thermocouple assembly is secured independently via a bracket onto the burner locating frame This can also be removed to prevent damage to the assembly Replace in reverse order ensuring all connections are gas tight...

Page 11: ...AC R2 001 Page 11 ...

Reviews: