Aurora Archer IS007 Installation & Operating Instructions Manual Download Page 38

COMPLETE UNIT WARRANTY 

DESCRIPTION 

 

 

WARRANTY PERIOD 

 

(FROM DATE OF PURCHASE) 

 

Heat Exchanger 

 

 

5 Years Parts/1 Year Labour 

Main Convection Fan 

 

2 Years Parts/1 Year Labour 

All Other Parts 

 

 

1 Year Parts/1 Year Labour 

 

AURORA WARRANTY PROGRAM 

To qualify for the Aurora Warranty Program, you need to fill out the warranty registration form, and have your qualified 
installer fill out the Installation Commissioning Report. Both documents must be returned promptly to Aurora Climate  
Systems. 
Please note, that Aurora Climate Systems will not accept responsibility for faults with the appliance caused through  
installation faults. We therefore strongly recommend that you return to Aurora Climate Systems the Installation  
Commissioning Report and obtain a Certificate of Compliance from your qualified installer for your protection. Failure to 
do so can void your warranty. 
 
It is the policy of Aurora that should a fault develop in the Archer Gas Log Space Heater during its warranty period, Aurora 
will at its own option either fix or repair the appliance in accordance with its present warranty policy. Also the policy of 
Aurora Climate Systems is if this Archer Gas Log Space Heater is found to be defective in materials or workmanship, 
Aurora Climate Systems will repair or replace such defects in the Archer Gas Log Space Heater at Aurora’s option in  
accordance with Aurora’s warranty policy. 
 

WARRANTY ON REPLACEMENT PARTS: 

Parts replaced under warranty are warranted for the balance of their original warranty period. 
 

DESIGNATION OF WARANTOR: 

This warranty is extended by Aurora Climate Systems with respect to the Archer Gas Log Space Heater as described here, 
while only in the possession of the original purchaser. 
 

PRODUCT: 

This Archer Gas Log Space Heater is comprised of the heater proper (including steel components and heat  
exchanger), fan assembly, electronic components and moving parts. Except where specifically excluded from coverage 
hereunder, this warranty covers all components designated. See Conditions, Exclusions and Qualifications below for further 
information on product coverage. 
 

CONDITIONS, EXCLUSIONS AND QUALIFICATIONS: 

Repair and replacement work will be carried out by the approved Service Agent of Aurora on the basis shown above,  
subject to proof of purchase and purchase date. Aurora will only accept claims under this warranty in strict accordance with 
the conditions set out below. 

 

1. 

Cost of travelling by service personnel in excess of 25km each way will apply if Aurora’s approved  service agent is 
situated more than 25km from the installation. In such circumstances, Aurora is not obligated to cover any additional 
travel or labour charges incurred by the service agent and such costs will need to be charged to the customer. 

 
2. 

The cost of transporting the Archer Gas Log Space Heater and parts between the nearest Aurora dealer or service 
agent and its normal location and where is it necessary for the product to be returned to the manufacturer and then 
returned back to the customer, these costs will be met by the customer. 

 
3. 

The cost of work or a service call where there is no fault with the heater, but where the defective operation or fault in 
the heater is due to incorrect plumbing/ electrical installation not in accordance with Aurora’s installation  
instructions and/or applicable local regulations, or where defects are caused by incorrect application, lack of  
operating knowledge, abuse of the appliance or abuse of the appliance or damage caused by the installer, or other 
persons attempting to install or repair the heater. 

 
4. 

In such cases, where Aurora Service Personnel attendance is required to correct faults in the product which are not 
directly related to product and/or parts failure but are the result of improper installation and lack of operating  
\knowledge of the appliance, Aurora Climate Systems will charge the purchaser of the appliance a fee calculated  on 
the basis of an $80.00 call out fee plus the labour rate of $60.00 per hour, as well as travelling expenses in excess of 
25km each way to rectify such faults. 

 
5.  Aurora expressly excludes any liability hereunder for defects or damaged caused by the 

 

installation on or of any components not expressly authorised and approved by Aurora. 

 

37 

Summary of Contents for Archer IS007

Page 1: ...IONS SAI Global Approval No GSCS20025 Australian Patent PN 200110001S Effective January 2009 Serial Number B D Number Model IS700 IS007 Aurora CLIMATE SYSTEMS A B N 43 108 083 987 PLEASE KEEP THESE IN...

Page 2: ...am 25 Safety Screen Installation 26 Insert Surround 27 OPERATING INSTRUCTIONS Automatic Humidifier Operation 28 Operating Instructions Checklist 29 30 Lighting Instructions 31 Fan Operation 32 Shutdow...

Page 3: ...ns Or if you wish clarification of the instructions contained in this manual please contact Aurora Climate Systems on telephone 03 9795 8895 or facsimile 03 9701 2088 Note As the Archer Gas Log Space...

Page 4: ...R GAS LOG SPACE HEATER Note If this appliance is installed by a licensed gas fitter who is not familiar on the installation of the heater we recommend that prior to installing the appliance the instal...

Page 5: ...HIS APPLIANCE DO NOT ENCLOSE THIS APPLIANCE Aurora Climate Systems A B N 43 108 083 987 71 73 Overseas Drive Noble Park VIC 3174 To be installed by an authorised person in accordance with installation...

Page 6: ...BSP Gas Connection Inside 4 3 sided Surround 885 x 742 5 Air Inlet Cover Plate 6 PVC Exhaust Pipe 40mm 7 Flue Exit Point centre line 8 Single Flue Adaptor 9 Single Flexi Flue suit 40mm pipe 10 Air In...

Page 7: ...he appliance to do so will void the warranty Note On Single Wall flue pipe installations imitation zero clearance fireplace a minimum of 25mm clearance must be provided at the rear of the heater to en...

Page 8: ...ion 0mm D Height Clearance From Unit 15mm 7 Note The Archer Gas Log Space Heater has been tested and approved for zero clearance to combustible materials Aurora Climate Systems recommends that clearan...

Page 9: ...4 Rear Burner 5 Front Burner NOTE Do not change position of front middle and rear logs as their positions have been present at the factory Changing log positions will result in faulty gas burner funct...

Page 10: ...and left hand cross logs Remove bottom grill See illustration below Note Please ensure the rear log is sitting hard up against the rear of the firebox at the base and at the top 2 Remove main door The...

Page 11: ...into position Note Ceramic logs are fragile and so to are the hot surface igniters underneath them and need to be handled with care at all times 6 Position left hand cross log No 5 in position as show...

Page 12: ...inst the rear at the firebox at the base and at the top B GAS PRESSURE FOR LPG Do not adjust gas burner pressure on LPG Gas burner pressure has been set at factory to required gas burner settings for...

Page 13: ...ipe installation if the unit and flue pipe is installed in line with the manufacturer s installation instructions Refer installation diagram for single flue pipe installations Pages 13 16 17 18 19 20...

Page 14: ...ER No Description Qty 1 Single Flue Adaptor 1 Supplied with heater 2 40mm PVC Pipe 400mm long 1 Supplied with heater 3 90 PVC Bend 1 Supplied with heater 4 40mm PVC Pipe up to 5 1m Supplied by install...

Page 15: ...the heater Note When connecting 40mm pipe at adaptor end and at cowl end ensure that 40mm pipe is long enough to fit in securely at both ends Failure to do so will cause the flames to go out and the h...

Page 16: ...place Note Do not use PVC cement to seal flue pipe connections to allow for removal of flue pipe Incorporate loop in gas connection or use flexible hose for gas connection to allow for removing of app...

Page 17: ...t be able to be removed easily for servicing Not locked in INTERNAL WALL APPLICATION 1 75mm Cowl 2 Flashing 3 BSP Gas Connection Flexible 4 40mm PVC Pipe Zero Clearance 5 45 PVC Elbow 6 45 PVC Elbow 7...

Page 18: ...length in 40mm PVC pipe 5100mm with 1 x 90 and 2 x 45 bends 90 Elbow 75mm stainless steel cowl to suit 40mm PVC flue pipe External Wall Concrete Slab Internal Wall INSTALLATION INSTRUCTIONS Internal t...

Page 19: ...m PVC pipe 5100mm with 1 x 90 and 2 x 45 bends Caution To avoid water trap in Flue system 40mm PVC pipe must be supported every 2 metres to avoid PVC pipe sagging and PVC pipe must have fall to ground...

Page 20: ...lexible Hose Nylaflow G P Hose Code AH50WAS Supplied with Flue Kit SFA002 Note I D Inside Diameter Flange attached to heater s exhaust fan Supplied and fitted to heater Note If adaptor not fitted dril...

Page 21: ...ue pipe being forced downwards Supplied by Installer Gas Cowl Supplied in flue kit For safety install gas cock next to appliance Use 1 2 gas loop or part loop in 1 2 copper pipe to allow unit to be re...

Page 22: ...wo burner switches is called the economy display mode and will only function when a Remote Control Thermostat has been installed in the heater The most common way this button is used is having the Rem...

Page 23: ...ng Remote Control Please Note The front panel must be opened for this wiring to occur The front panel simply pulls forward no tools required Caution When removing front panel as there are low voltage...

Page 24: ...met supplied over gas line and insert into back panel IMPORTANT Note The copper gas supply line to the heater must be installed under conditions which will allow for easy removal of the heater from it...

Page 25: ...s pressure Note Gas burner pressure can only be adjusted on high burner setting with both switches medium and low burner in the ON position and flames holding on both burners B represents the test poi...

Page 26: ...14 WAY RIBBON TO DISPLAY 1 CONV FAN BLUE 2 TR PRIMARY BLACK TR PRIMARY WHITE 8 1 N C 2 3 1 TRANSFORMER 12V AIR PRESSURE SWITCH REAR BURNER SWITCH PIN 5 FRONT BURNER SWITCH TRANSFORMER 240V PIN 18 PIN...

Page 27: ...NS OR CLOTHING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE ALWAYS ENSURE THAT YOUR SAFETY SCREEN SUPPLIED WITH THE HEATER IS FITTED TO THE MA...

Page 28: ...e when fitting the surround to heater FITTING OF LOUVRE Place the louvre in the surround as shown in Diagram A and fasten with the six screws supplied as shown in Diagram B DIAGRAM B FITTING OF SURROU...

Page 29: ...e automatic humidifier pump comes on to pump condensate into the stainless steal tray located on the top of the heater the L E D light Item 10 on the front panel will light up and flash for the durati...

Page 30: ...operating incorrectly causing a safety hazard and will void the manufacturer s warranty of the appliance 6 Check and inspect the appliance for gas leaks In the event of gas leaks cut off the gas supp...

Page 31: ...s fitted as heater will not operate 14 For your personal safety check and verify that polarities are correct in the power supply to the heater Also check for proper earth connections at the power sour...

Page 32: ...ight and the convection fan will blow warm air from the heater as the heater becomes warmer the medium L E D Item 8 will come on and when the heater has reached its highest operating temperature all t...

Page 33: ...te It can take up to approximately 20 30 minutes before the fan speed will change and settle on the next setting The firebox temperature and the outside ambient temperature will regulate how quickly t...

Page 34: ...IRING The first fire in your heater is part of the paint curing process Your Archer Gas Log Space Heater has been painted with the highest quality heat resistant silicon paint available in the world T...

Page 35: ...for the heater to do in certain situations Eg Overheating power failure or dips windy conditions pump failure partial or full blockage of flue pipe or no gas All of these operations are monitored by t...

Page 36: ...ced and cleaned annually by a qualified service person to ensure that your appliance is operating efficiently Note If the main convection fan becomes clogged with lint and dust an over temperature sit...

Page 37: ...y Stainless Steel doors can be cleaned with a metal cleaner that can be used on Stainless Steel Please note Stains or imperfections on plated finishes are not covered under warranty Caution Do not use...

Page 38: ...d Qualifications below for further information on product coverage CONDITIONS EXCLUSIONS AND QUALIFICATIONS Repair and replacement work will be carried out by the approved Service Agent of Aurora on t...

Page 39: ...tion or functionality check Freight or postage both ways is to be paid by the owner If Aurora finds a fault with the device they will repair or replace it under the normal warranty terms 1 Year It mus...

Page 40: ...11 Sooting up of heater Note For heaters operating on LPG to avoid sooting up of heater LPG bottle must not be run empty For best practice LPG bottles should be refilled after 75 of fuel has been use...

Page 41: ...ion for the learn process to occur The burner switches and the red button must all be in the OFF position When removing or replacing the front panel ensure no wires are disconnected broken or pinched...

Page 42: ...normal No If the glass has sooted up that you start having difficulty seeing through it this is not normal Nor is having large build up of soot forming on the logs Please note It is normal for some so...

Page 43: ...NOTES 42...

Page 44: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING INSTALLATION INSTRUCTIONS TO THE CONSUMER FOR FUTURE REFERENCE DATE OF PURCHASE...